Skip to content
SunGeneAgricultural IoT
← All products
Single-Phase Smart Energy Meter

Single-Phase Smart Energy Meter

Equipment options & specifications

Single-phase direct-connected smart meter for commercial and residential submetering, with plug-in PLC, RF or cellular communication modules and optional RS485 for remote reading.

Appearance, connectors and included accessories follow the configuration confirmed in your quotation.

Related application hardware: Energy Monitoring

Specifications & version options

Electrical system
Single-phase two-wire; 220 / 230 / 240 VAC; 50 Hz
Voltage range
0.6-1.2 Un
Current
0.25-5(100) A direct-connected; starting current 0.4% Ib
Accuracy
Class 1 active energy; Class 2 reactive energy
Communication
Plug-in PLC / RF / GPRS / 3G / LTE; RS485 and infrared optional
Meter functions
Import / export energy, multi-tariff, maximum demand, event and load-control functions
Show 3 more specification rows

Need to connect this equipment to an existing controller or platform?

Share your current model, a photo or the connection you need. We help assess interfaces, power and the required configuration.

Get selection & integration help

Buying this equipment

Samples & minimum quantity
Ask for a sample or a small pilot. Availability, minimum quantity and sample charges depend on the selected model.
Price & delivery
Range, interface, accessories, quantity and destination affect the quote. Stock, lead time, freight, taxes and delivery terms need confirmation.
Warranty & support
Coverage, duration, exclusions and the fault-assessment process are confirmed for the quoted model before order.
Certificates & documents
Tell us the destination and required standard. We check the exact model, document revision and available evidence; a family listing is not certification.
Review procurement and support details →

Find the right document

Public documents describe this product family and selection options. Wiring, register maps and compliance documents must match the model and version selected for your order.

Open family selection sheet

English · Web page · printable
Current online selection reference

Open selection catalog

Industrial Monitoring Hardware Catalog
PDF · English · 379 KiB
File revision: 2026-07-22 · 85c5f07896ab

Need documents for engineering or purchasing?

Choose what you need. We first identify the model and revision, then confirm which documents can be supplied. The request does not imply that every document is available.

Public now
Public selection guidance and model-selection catalogue
Check for the selected model
Exact-model datasheet · Wiring / pinout · Register map, protocol or sample data · Model-specific certificates · Calibration and measurement evidence · Dimensions / installation drawing
Project starter files →
Request an engineering package →
From a product family to your order
  1. Family page

    Compare uses, interfaces and configuration options. These are selection references.

  2. SG reference

    An SG code helps identify a sourcing option; it is not a substitute for the manufacturer model or its certificate.

  3. Written quotation

    Confirm the exact model, configuration, photograph, document revisions, accessories, price, delivery and warranty.

Get selection help

Start with a short description. A complete equipment list is not required.

Text stays in this tab for up to 30 minutes while you browse. Saving across reloads is optional below.

A personal email is welcome.

A country and general site description are enough. If the location is undecided, say so.

Up to 5 files, 10 MB each. PDF, JPG, PNG, WebP, CSV, TXT, DOCX or XLSX.

By submitting this form, you acknowledge the privacy notice.

See where the system fits

Equipment in the system

System design, software integration, PLC/SCADA programming and site installation responsibilities are agreed in the written project scope.

How the model is selected

The written quotation ties the site requirement to one reviewed hardware configuration.

Site requirement

Application, medium, mounting and environment

Hardware configuration

Signal, protocol, power and enclosure

Quote confirmation

Model, quantity, certificates and delivery

remote-monitoring integration with field enclosure, gateway, power and industrial equipment

Remote integration context

Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.

What the reviewed configuration proves

The reviewed source is a modular single-phase direct-connected smart meter with selectable communication hardware.

  • The electrical topology is single-phase two-wire. Three-phase circuits and DIN-rail installations require a different meter family.
  • The reviewed current specification is 0.25-5(100) A for direct connection; it is not an external-CT meter configuration.
  • PLC, RF and cellular communications are plug-in configuration choices. They are not simultaneous built-in 4G, LoRaWAN and Wi-Fi features.
Show 2 more reviewed selection notes

Model-selection reference

Industrial Monitoring Hardware Catalog

Compare equipment options in this catalog section.

Open this catalog section
Catalog section
Energy metering and current sensing
equipment references
22
PDF pages
31–34

SG codes for enquiry

22 sourcing references from “Energy metering and current sensing”. Put an SG code in the RFQ so we can match the same catalog row.

  • SG-EM-129
  • SG-EM-131
  • SG-EM-140
  • SG-EM-157
  • SG-EM-165
  • SG-EM-176
  • SG-EM-178
  • SG-EM-196
  • SG-EM-200
  • SG-EM-206
  • SG-EM-208
  • SG-EM-212
  • SG-EM-214
  • SG-EM-215
  • SG-EM-218
  • SG-EM-220
  • SG-CTD-101
  • SG-CTD-109
  • SG-CTD-119
  • SG-CTD-152
  • SG-CTD-171
  • SG-CTD-192
Open this catalog section

Continue product selection

Compare adjacent hardware families for the same monitoring path.

How to choose

  • Use this reviewed product only for a single-phase two-wire circuit. Specify a different meter family for three-phase or external-CT architectures.
  • Confirm 220, 230 or 240 VAC service and a direct-connected current within 0.25-5(100) A.
  • State whether readings are for operational monitoring, tenant allocation or regulated billing; local accuracy, metrology and utility acceptance requirements differ.
  • Choose one documented plug-in communication path - PLC, RF or cellular - from the site network and destination-market requirements. RS485 is optional.
Show 2 more selection checks

Compatible with

  • Single-phase two-wire 220 / 230 / 240 VAC circuits within the reviewed direct-current range
  • Plug-in PLC, RF or cellular communication modules selected for the project
  • Optional RS485 and infrared local communication interfaces
  • AMI or customer data systems after the protocol, point list and integration responsibility are confirmed

Typical package

  • Single-phase direct-connected smart meter
  • Selected plug-in PLC, RF or cellular communication module
  • Optional RS485 interface where required by the data path
  • Meter box, upstream protection, isolation and wiring accessories selected by the local electrical design
  • Integration checklist covering protocol, credentials, endpoint, reporting interval and acceptance readings

Applications

facility energy-monitoring panel with meters, current sensors and an RS485 gateway
Electrical ratings, current-sensor arrangement, gateway and panel wiring are confirmed before quotation.

Use this meter for single-phase commercial or residential energy measurement when remote reading is required through a selected communication module. Choose a separate three-phase or DIN-rail meter family for those circuit and mounting requirements. Communication, metering purpose and local approval requirements are confirmed before quotation.

  • Single-phase commercial and residential remote meter reading
  • Distributed submetering where each point requires a local display and selectable communications
  • AMI retrofit projects using project-specific PLC, RF or cellular modules
  • Operational energy monitoring when the customer system can accept the confirmed meter protocol
See related application hardware

What to include in your quote request

  • Single-phase two-wire service voltage and frequency
  • Maximum direct-connected current within 0.25-5(100) A
  • Operational monitoring, allocation or regulated billing use
  • Required PLC, RF, cellular, RS485 or infrared communication path
  • Destination country, carrier or network constraints
  • Protocol, point list, reporting interval, endpoint and credential ownership
  • Meter-box space, protection, isolation, quantity and project stage
Request Hardware Quotation

Related selection guides

Related resources

Frequently asked questions

Can this be configured as a wireless IoT energy meter?

Yes. A reviewed plug-in RF or cellular module can provide the remote communication path. PLC and optional RS485 are separate project configurations, and the ordered module, protocol, carrier or frequency must be confirmed before quotation.

Is this a three-phase DIN-rail energy meter?

No. The reviewed hardware is a single-phase two-wire direct-connected smart meter. Use a separate reviewed three-phase meter family when the circuit is three-phase.

Which remote communication options are available?

The reviewed source documents plug-in PLC, RF and cellular communication modules, plus optional RS485 and infrared interfaces. The ordered module and protocol are confirmed for the destination network and integration.

Can it upload directly to any cloud platform?

That is not assumed. The communication module, protocol, endpoint, credentials, reporting interval and data ownership must be reviewed with the target system before quotation.

What current range does the reviewed meter support?

The reviewed direct-connected configuration is rated 0.25-5(100) A. Circuits outside that range require a different meter or CT-operated architecture.

Can this meter be used for revenue billing?

Only after the required accuracy, local metrology rules, utility acceptance and certification for the destination market have been confirmed. The website does not claim universal billing approval.

What should I provide when requesting a quote for the Single-Phase Smart Energy Meter?

Single-phase two-wire service voltage and frequency; Maximum direct-connected current within 0.25-5(100) A; Operational monitoring, allocation or regulated billing use; Required PLC, RF, cellular, RS485 or infrared communication path

Where can I compare available model options?

Open the Industrial Monitoring Hardware Catalog linked on this page. Use it to compare equipment options before requesting a configuration.

Will it work with my existing system?

Compatibility is reviewed against your field signals, protocols and upstream platform. Typical pairings include Single-phase two-wire 220 / 230 / 240 VAC circuits within the reviewed direct-current range, Plug-in PLC, RF or cellular communication modules selected for the project, Optional RS485 and infrared local communication interfaces.

Product-family reference. Final ordered model and specifications are confirmed in the written quotation.