More measurements
Analog and temperature modules collect level, pressure, temperature and other documented signals from the installed transmitters.
Distributed Remote I/O System — connection diagram.
DIN-rail distributed I/O with separate PROFINET or EtherCAT coupler configurations and expansion modules selected from the project I/O schedule.
Related application hardware: Farm pump & energy monitoring
Farm equipment configurations
Use remote I/O where a greenhouse or pump cabinet needs more inputs and outputs. Select the network coupler first, then match each module to the signal and the compatible module bus.
Analog and temperature modules collect level, pressure, temperature and other documented signals from the installed transmitters.
Digital inputs read run, fault, limit-switch and contact states. Match dry contacts, wet contacts, NPN and PNP inputs to the circuit.
Choose relay, transistor or analog output modules to match the receiving equipment. Keep the local protection and interlocks in the control design.
Open an equipment type to compare its configurations. The quotation identifies the complete device, interfaces and accessories.
Distributed inputs for an existing Modbus TCP farm controller.
Request this configuration →Equipment: Dual Ethernet, RS485 and up to 32 compatible bus modules; 24 VDC.
Include with your request: Use the coupler’s matching module bus; IP20 panel installation.
Expose greenhouse or pump measurements to an OPC UA client.
Request this configuration →Equipment: OPC UA server, dual Ethernet, RS485 and up to 32 compatible bus modules; 24 VDC.
Include with your request: Client requirements, node mapping and compatible bus modules.
Equipment: EtherNet/IP slave, dual Ethernet, RS485 and up to 32 compatible bus modules.
Include with your request: PLC network, process-data size and matching module bus.
Distributed farm equipment I/O on an existing EtherCAT network.
Request this configuration →Equipment: EtherCAT slave and up to 32 compatible bus modules.
Include with your request: Master compatibility, network topology and matching module bus.
Level, pressure and other analog transmitters in one cabinet.
Request this configuration →Equipment: Separate 0/4–20 mA or 0–5/0–10 V versions; 16-bit inputs.
Include with your request: Select one input version and its compatible coupler.
Run, fault and limit-switch contacts across greenhouse equipment.
Request this configuration →Equipment: Separate low-level, high-level and dry-contact versions.
Include with your request: The selected input circuit and common-terminal wiring.
Control-panel signals for valves and other interface circuits.
Request this configuration →Equipment: Separate PNP sourcing or NPN sinking versions; up to 200 mA per channel.
Include with your request: Load type, external supply and matching coupler.
Isolated switching contacts for an equipment control panel.
Request this configuration →Equipment: 8 relays; maximum 2 A per channel; maximum 250 VAC / 30 VDC.
Include with your request: Actual load rating and the local protection circuit.
Analog setpoint signals for compatible field equipment.
Request this configuration →Equipment: 0–20 mA or 4–20 mA output; 16-bit resolution.
Include with your request: Receiving input range and compatible coupler.
Analog setpoints for equipment with the corresponding voltage input.
Request this configuration →Equipment: −5 to +5 V or −10 to +10 V output; 16-bit resolution.
Include with your request: Use the correct voltage-input circuit and compatible coupler.
Temperature points around crop-storage or greenhouse equipment.
Request this configuration →Equipment: 3- or 4-wire RTD inputs; PT100 and PT1000 versions.
Include with your request: Sensor type, wire count and compatible coupler.
Multiple thermistor measurements in one cabinet.
Request this configuration →Equipment: 8 two-wire NTC inputs; 16-bit resolution.
Include with your request: Thermistor characteristics and compatible coupler.
A few temperature points without a large modular rack.
Request this configuration →Equipment: 4 PT100/PT1000 channels; 2- or 3-wire sensors.
Include with your request: Network protocol, sensor wiring and supply version.
Equipment: 6 PT100/PT1000 channels; 2-, 3- or 4-wire sensors.
Include with your request: Communication interface, sensor wiring and supply version.
More temperature points along a wired farm network.
Request this configuration →Equipment: 8 PT100/PT1000 channels; 2- or 3-wire sensors; dual Ethernet.
Include with your request: Network protocol, sensor wiring and supply version.
Collect contact signals near the field equipment.
Request this configuration →Equipment: 8 DI, Modbus RTU, 9–36 VDC. Potted cable version: IP67. Tool-free terminal version: IP65.
Include with your request: Choose the enclosure and cable version separately.
Bring nearby sensor signal cables into one multicore cable.
Request this configuration →Equipment: 2 signal channels per port; 24 VDC; prefabricated cable version.
Include with your request: NPN/PNP wiring and controller input compatibility; this is a wiring distributor.
Reduce separate field cable runs around a greenhouse equipment group.
Request this configuration →Equipment: 1- or 2-channel prefabricated cable versions; 1-channel tool-free terminal version; 24 VDC.
Include with your request: Choose the port, channel and termination version; it is not a network gateway.
A small group of contacts and transmitters near farm equipment.
Request this configuration →Equipment: 2 digital inputs, 2 analog inputs and 2 digital outputs; Ethernet module configuration.
Include with your request: Required network protocol, analog ranges and output circuit.
Read status contacts and provide a few control-panel outputs.
Request this configuration →Equipment: 4 digital inputs and 4 digital outputs.
Include with your request: Network protocol, contact types, output circuit and power.
Connect transmitters and analog setpoints in a farm cabinet.
Request this configuration →Equipment: 4 DI, 4 AI, 4 DO and 2 AO.
Include with your request: Input/output ranges, network protocol, supply and local control design.
Collect equipment run/fault contacts and panel outputs.
Request this configuration →Equipment: 8 digital inputs and 4 digital outputs.
Include with your request: Interface, network protocol, contact types and output loads.
More contact and output points around a greenhouse equipment group.
Request this configuration →Equipment: 8 digital inputs and 8 digital outputs.
Include with your request: Interface, network protocol, contact types and output loads.
Combine hardwired status and analog transmitter measurements.
Request this configuration →Equipment: 8 digital inputs, 4 analog inputs and 4 digital outputs.
Include with your request: Input ranges, protocol, supply and output circuit.
A larger mixed-signal equipment group in one farm cabinet.
Request this configuration →Equipment: 8 digital inputs, 8 analog inputs and 8 digital outputs.
Include with your request: Input ranges, protocol, supply and output circuit.
Collect four analog farm transmitters.
Request this configuration →Equipment: 4 AI; 0/4–20 mA or 0–5/0–10 V input configurations.
Include with your request: Select the input ranges, interface, network protocol and power.
Collect a larger group of level, pressure or other analog signals.
Request this configuration →Equipment: 8 AI; 0/4–20 mA or 0–5/0–10 V input configurations.
Include with your request: Select the input ranges, interface, network protocol and power.
Read equipment contacts without a large modular rack.
Request this configuration →Equipment: Separate 4-, 8- and 16-input network modules.
Include with your request: Contact circuit, protocol, interface and power for the selected version.
Provide additional outputs to the farm equipment panel.
Request this configuration →Equipment: Separate 4-, 8- and 16-output network modules.
Include with your request: Output type, load limits, interface, protocol and local interlocks.
Add relay contacts and digital outputs to a farm control cabinet.
Request this configuration →Equipment: 8 digital outputs and 8 relay channels.
Include with your request: Output circuit, relay loads, network protocol and panel protection.

Connect compatible field signals to the selected collector. Start with the sensors and controller already on site, then agree units, timestamps and the destination for each reading.
Farm teams can use the same collection approach for remote irrigation and weather points. The required interfaces, power, network and buffering behavior must match the selected device.
The quotation lists the selected equipment, accessories, price and delivery terms.
Purchasing and delivery details →Selection guidance and application documents. Wiring, register maps and certificates must match the chosen model and version.
English · Web page · printable
Online selection guide
Application selection guide
PDF · English
Tell us which wiring, protocol or calibration documents you need for the equipment.
Compare uses, interfaces and configuration options. These are selection references.
Define the required function, interfaces, power, mounting and accessories for the site.
Confirm the exact model, configuration, photograph, document revisions, accessories, price, delivery and warranty.
Tell us what you want to measure and where. Send a model number or site photo if you have one.
Example equipment arrangement. Check compatibility and agree who handles software, PLC/SCADA programming and site installation.
Data destination
Customer platform or an agreed third-party service
Compare power, communication and equipment requirements for irrigation, pumps, soil and weather monitoring.

Product photograph
Pictured: SG-VIB-114 — Industrial Accelerometer for Vibration Monitoring.
Compare related equipment and connection options.

Product photograph. Pictured: SG-RTU-157 — Industrial Telemetry Remote Terminal Unit.
Use a distributed remote I/O station when field signals need to be collected close to the machine or cabinet and returned to a PLC over industrial Ethernet. Select one controller-side coupler first, then build the station from the actual I/O schedule; PROFINET and EtherCAT are separate configurations rather than simultaneous protocols.
No. PROFINET and EtherCAT are separate coupler configurations. Select the coupler that matches the PLC network, then build the station from the required I/O modules.
This product family includes switching, analog, PT100, K-type thermocouple and encoder expansion modules. Exact channel counts and module order are taken from the project I/O schedule.
No. A bus module needs its matching coupler or controller. Internal expansion boards, bus-mounted modules and standalone Ethernet or RS485 modules use different connection architectures.
Send the existing controller or coupler, network protocol, number of channels, input and output signal types, sensor wire counts, field supply and cabinet conditions.
Use the listed inputs, power and protocol to match the device to your controller. Send its model or an input photo with the equipment request.