Final configuration is confirmed in the quotation.
Ultrasonic Weather Station
Configurable 5-, 6- or 9-channel weather instrument with mandatory ultrasonic wind measurement and a selected RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12 interface.
Start with the information you have. Exact model, interface and certificates are confirmed in writing before order.
Image details
Representative ultrasonic weather-instrument visual derived from reviewed exact-model documents and independently de-identified. It is not the final ordered-model photograph; channel set, output, protocol, heater, positioning functions, cable, mounting, markings and certificates are confirmed in the quotation.
Related solution: Environmental Monitoring
Where the hardware sits in the monitoring path
A planning view, not a fixed bundle. Signal type, protocol, power, network and the customer endpoint are confirmed before quotation.
Customer system
SCADA, BMS or customer-owned platform
Specifications
- Channel sets
- 5, 6 or 9 channels; wind speed and direction are mandatory
- Five-channel set
- Wind speed, wind direction, air temperature, relative humidity and atmospheric pressure
- Optional channels
- Precipitation; on the reviewed 9-channel set: solar radiation, illuminance and dust
- Wind speed
- 0–60 m/s; 0.01 m/s resolution; ±2% FS accuracy
- Wind direction
- 0–360°; 1° resolution; <3° accuracy
- Air temperature
- -40 to +80 °C; ±0.5 °C accuracy
Show 9 more specification rows
How the model is selected
The written quotation ties the site requirement to one reviewed hardware configuration.
Site requirement
Application, medium, mounting and environment
Hardware configuration
Signal, protocol, power and enclosure
Quote confirmation
Model, quantity, certificates and delivery

Remote integration context
Representative site context. Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.
Select the channels and interface before treating this as one weather station
The reviewed documents describe a configurable instrument family, not one universal all-channel configuration.
- Wind speed and wind direction are mandatory. The five-channel set adds air temperature, relative humidity and atmospheric pressure; the six-channel set adds precipitation; the nine-channel set adds precipitation, solar radiation, illuminance and dust.
- RS485, RS232 and SDI-12 are alternatives, not simultaneous standard outputs. Modbus RTU is the default reviewed protocol for RS485; NMEA-0183 and SDI-12 require their matching ordered interface.
- The base instrument is below 3 W in the reviewed documents. Optional ultrasonic-head heating and added sensor modules change the site power budget and must be sized separately.
Show 2 more reviewed selection notes
Model-selection reference
Agriculture & Weather Hardware Catalog
Use this audited section to compare available hardware configurations. The representative website image is not an exact model photograph; the ordered configuration is confirmed in the quotation.
- Catalog section
- All-in-one weather stations
- SG-coded options
- 18
- PDF pages
- 5–7
Continue product selection
Compare adjacent hardware families for the same monitoring path. The final combination is checked against the project I/O, protocol, power and enclosure requirements.
How to choose
- Choose the 5-, 6- or 9-channel set from the decisions the station must support. Wind speed and direction are mandatory; precipitation, solar radiation, illuminance and dust are configuration-dependent.
- Select one matching interface and protocol path: RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12. Do not assume all outputs are installed together.
- Review wind performance, optional precipitation needs, heater use, site climate, mast rigidity, obstacle clearance, grounding and lightning / surge protection.
- Size 12-24 VDC field power from the base instrument plus any heater and optional sensor modules, then match the logger, RTU or gateway to the required update and reporting interval.
Show 1 more selection checks
Compatible with
- RS485 Modbus RTU loggers, PLCs, RTUs and gateways when that interface is selected
- RS232 receivers using the selected NMEA-0183 output, or SDI-12 data loggers on the ordered SDI-12 configuration
- 12-24 VDC field power with project-sized cable, grounding and surge protection
- Fixed mast installations; mobile platforms only after the optional positioning and orientation functions are reviewed
Typical package
- One integrated ultrasonic weather instrument with the selected 5-, 6- or 9-channel measurement set
- One ordered output and protocol combination: RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12
- Project-selected cable, mast adapter or mounting hardware, grounding and surge protection
- Customer logger or a selected RTU / gateway, plus field power and backhaul hardware when required
- Heater, precipitation, radiation, illuminance, dust, positioning and orientation functions only when specified in the quotation
Applications

Use this integrated instrument when a site needs ultrasonic wind measurement plus a selected weather-data set in one compact mast-mounted housing. Wind speed and direction are mandatory; temperature, humidity and pressure form the standard five-channel set, while precipitation or the broader nine-channel set are ordered only when the project needs them. The output, protocol, heater, positioning functions, cable and mounting package are selected together rather than assumed from the enclosure image.
- Unattended agricultural, environmental and field-weather monitoring stations
- Solar- and wind-site operating-condition monitoring linked to a customer logger, RTU or SCADA system
- Traffic, port, vessel or mobile-platform projects after positioning, orientation and mounting are reviewed
- Compact weather inputs for customer-owned data platforms where a selected serial protocol is already defined
What to include in your quote request
- Required 5-, 6- or 9-channel parameter set and decision / accuracy target
- Fixed mast or moving platform, site coordinates, climate, mounting height and nearby obstructions
- Selected RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12 interface and the connected logger / RTU
- Precipitation, heater, positioning, electronic-compass and other optional-module requirements
- Sampling / update cycle, reporting interval, destination SCADA / platform and offline behavior
- Available 12-24 VDC supply, cable length, grounding, surge / lightning protection and backhaul
- Quantity, destination country, calibration / acceptance documents and project timing
Related selection guides
Related resources
Frequently asked questions
Which measurements are included in the ultrasonic weather station?
Wind speed and direction are mandatory. The reviewed five-channel set adds air temperature, relative humidity and atmospheric pressure. A six-channel set adds precipitation, while the reviewed nine-channel set additionally includes solar radiation, illuminance and dust. The quotation identifies the exact ordered channels.
Can it connect to a Modbus RTU logger or gateway?
Yes, when the RS485 Modbus RTU configuration is selected. RS232 NMEA-0183 and SDI-12 are separate interface / protocol choices; they are not assumed to be available simultaneously.
Can the instrument be installed on a vehicle or vessel?
A mobile installation can be reviewed with the optional GPS / BDS and electronic-compass functions. Mounting rigidity, orientation, motion compensation, power and the receiving system must be checked for the specific platform.
Does IP66 mean the weather station is maintenance-free?
No. The ultrasonic wind path has no rotating cups or vane, but the installed system still requires obstruction clearance, sound mounting, grounding, surge protection and periodic inspection. Optional precipitation and other sensing channels may add their own cleaning or inspection needs.
What should I provide when requesting a quote for the Ultrasonic Weather Station?
Required 5-, 6- or 9-channel parameter set and decision / accuracy target; Fixed mast or moving platform, site coordinates, climate, mounting height and nearby obstructions; Selected RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12 interface and the connected logger / RTU; Precipitation, heater, positioning, electronic-compass and other optional-module requirements
Where can I compare available model options?
Open the Agriculture & Weather Hardware Catalog linked on this page. It lists audited SG-coded selections; the ordered configuration is confirmed in the quotation.
Will it work with my existing system?
Compatibility is reviewed against your field signals, protocols and upstream platform. Typical pairings include RS485 Modbus RTU loggers, PLCs, RTUs and gateways when that interface is selected, RS232 receivers using the selected NMEA-0183 output, or SDI-12 data loggers on the ordered SDI-12 configuration, 12-24 VDC field power with project-sized cable, grounding and surge protection.