Skip to content
SunGene Industrial Remote Monitoring HardwareSunGeneIndustrial hardware
All products
Three-Phase Direct-Connected Smart Energy Meter
Representative image

Final configuration is confirmed in the quotation.

Three-Phase Direct-Connected Smart Energy Meter

Specifications checked against source documents

Direct-connected three-phase four-wire energy meter for circuits up to 100 A, with an RS485 hardware option for verified remote-reading integrations.

Start with the information you have. Exact model, interface and certificates are confirmed in writing before order.

Image details

Representative direct-connected three-phase meter visual derived from a reviewed exact-model reference and independently de-identified. It is not the final ordered-model photograph; wiring, communication module, protocol profile, display data, markings and certificates are confirmed in the quotation.

Related solution: Energy Monitoring

Where the hardware sits in the monitoring path

A planning view, not a fixed bundle. Signal type, protocol, power, network and the customer endpoint are confirmed before quotation.

Specifications

Connection
Three-phase four-wire, direct-connected
Nominal voltage
220 / 230 / 240 VAC phase-voltage references; 0.6–1.3 Un operating range
Frequency
50 Hz ±5%
Current
0.25–5(100) A; starting current 0.4% Ib
Energy accuracy
Active Class 1; reactive Class 2
Pulse constants
1000 imp/kWh and 1000 imp/kvarh
Show 5 more specification rows

How the model is selected

The written quotation ties the site requirement to one reviewed hardware configuration.

Site requirement

Application, medium, mounting and environment

Hardware configuration

Signal, protocol, power and enclosure

Quote confirmation

Model, quantity, certificates and delivery

Representative remote-monitoring integration with field enclosure, gateway, power and industrial equipment

Remote integration context

Representative site context. Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.

Confirm the wiring and communication configuration

The reviewed source supports a direct-connected meter family. It does not prove that every optional communication module or protocol is installed in every unit.

  • Use this selection for three-phase four-wire direct connection up to 100 A; use a CT-operated meter for higher-current circuits.
  • The reviewed current range is 0.25–5(100) A, with active-energy Class 1 and reactive-energy Class 2.
  • The nominal phase-voltage references are 220 / 230 / 240 VAC, with an operating range of 0.6–1.3 Un; confirm the destination wiring standard before quotation.
Show 3 more reviewed selection notes

Model-selection reference

Industrial Monitoring Hardware Catalog

Use this audited section to compare available hardware configurations. The representative website image is not an exact model photograph; the ordered configuration is confirmed in the quotation.

Open this catalog section
Catalog section
Energy metering and current sensing
SG-coded options
22
PDF pages
31–34

Continue product selection

Compare adjacent hardware families for the same monitoring path. The final combination is checked against the project I/O, protocol, power and enclosure requirements.

How to choose

  • Confirm a three-phase four-wire supply, the phase voltage and whether the circuit can use a direct-connected meter.
  • Use this reviewed configuration only within 0.25–5(100) A. Specify a CT-operated meter instead when the circuit exceeds 100 A or site isolation rules require it.
  • State whether the data is for operational monitoring, tenant allocation or regulated billing so accuracy and certification requirements can be reviewed.
  • RS485 hardware does not by itself prove Modbus compatibility. Provide the required platform, protocol and point list so the data profile can be verified.
Show 2 more selection checks

Compatible with

  • Three-phase four-wire installations within the reviewed voltage and current range
  • RS485 data collectors when the selected interface and protocol are confirmed
  • Infrared, PLC, RF or cellular communication modules only when included in the quotation
  • Customer AMI, HES or energy platform after the data profile and protocol map are reviewed

Typical package

  • Selected direct-connected three-phase meter
  • Meter-box, protection and terminal wiring plan
  • Selected RS485 or optional communication module
  • Protocol profile and commissioning test record

Applications

Representative facility energy-monitoring panel with meters, current sensors and an RS485 gateway
Representative facility-metering context. Electrical ratings, current-sensor arrangement, gateway and panel wiring are confirmed before quotation.

This reviewed three-phase four-wire meter is a direct-connected option for circuits up to 100 A, where an external current transformer is not required. It is suited to facility sub-metering and remote energy collection after the site voltage, wiring, current and communication configuration have been confirmed.

  • Facility and building sub-metering on direct-connected three-phase circuits
  • Remote meter reading through a confirmed RS485 or optional communication module
  • Operational energy monitoring for panels, equipment groups and distributed sites
  • Import / export and multi-rate metering only when the quoted configuration includes those functions
See the full solution

What to include in your quote request

  • Three-phase four-wire topology, phase voltage and frequency
  • Maximum circuit current and confirmation that direct connection is acceptable
  • Operational monitoring, allocation or regulated billing use
  • Required measurements, accuracy and local certification requirements
  • RS485 or optional communication path, protocol, point list and destination platform
  • Meter-box space, protection, isolation and wiring constraints
  • Destination country, quantity, sample / pilot / production stage and delivery target
Request a Quote

Related selection guides

Related resources

Frequently asked questions

What does direct-connected mean for this three-phase energy meter?

The reviewed meter carries the circuit current directly through its meter terminals and is specified for 0.25–5(100) A. It does not require external current transformers within that reviewed range. Higher-current circuits need a CT-operated meter instead.

Does this meter support RS485 Modbus?

The reviewed source confirms an RS485 hardware option but does not publish a verified Modbus protocol or register map. If Modbus integration is required, include the target gateway or platform and required points in the RFQ so the protocol profile can be verified before quotation.

Is a cellular communication module built in?

Not necessarily. Infrared, PLC, RF and 2G / 3G / 4G communication paths are configuration-dependent options. The regional module, operator bands, antenna and data interface are selected and documented in the quotation.

What should I provide for meter selection?

Provide the three-phase wiring, phase voltage, maximum current, monitoring or billing purpose, required measurements, communication path, destination platform, meter-box dimensions, quantity and destination country.

What should I provide when requesting a quote for the Three-Phase Direct-Connected Smart Energy Meter?

Three-phase four-wire topology, phase voltage and frequency; Maximum circuit current and confirmation that direct connection is acceptable; Operational monitoring, allocation or regulated billing use; Required measurements, accuracy and local certification requirements

Where can I compare available model options?

Open the Industrial Monitoring Hardware Catalog linked on this page. It lists audited SG-coded selections; the ordered configuration is confirmed in the quotation.

Will it work with my existing system?

Compatibility is reviewed against your field signals, protocols and upstream platform. Typical pairings include Three-phase four-wire installations within the reviewed voltage and current range, RS485 data collectors when the selected interface and protocol are confirmed, Infrared, PLC, RF or cellular communication modules only when included in the quotation.