Skip to content
SunGene Industrial Remote Monitoring HardwareSunGeneIndustrial hardware
All products
LoRaWAN Temperature & Humidity Data Logger
Representative image

Final configuration is confirmed in the quotation.

LoRaWAN Temperature & Humidity Data Logger

Specifications checked against source documents

Battery-powered LoRaWAN temperature and humidity logger with built-in flash, BLE 5.0 setup, selectable regional bands and reviewed ±0.2 °C temperature accuracy.

Start with the information you have. Exact model, interface and certificates are confirmed in writing before order.

Image details

Representative LoRaWAN temperature-and-humidity logger visual derived from an exact-model reference and independently redesigned without supplier identifiers. It is not the final ordered model; radio region, sensor probe, enclosure, battery and reporting configuration are confirmed in the quotation.

Related solution: Equipment Monitoring

Where the hardware sits in the monitoring path

A planning view, not a fixed bundle. Signal type, protocol, power, network and the customer endpoint are confirmed before quotation.

Specifications

Measurement
Temperature and relative humidity; external-probe version available
Temperature accuracy
±0.2 °C from 0 to 60 °C
Humidity accuracy
Typical ±1.8%
LoRaWAN
Version 1.0.3; EU868 / AU915 / US915 / AS923 / IN865 / KR920 / RU864
Local configuration
Bluetooth 5.0
Offline records
Built-in flash with upload after connectivity returns
Show 3 more specification rows

How the model is selected

The written quotation ties the site requirement to one reviewed hardware configuration.

Site requirement

Application, medium, mounting and environment

Hardware configuration

Signal, protocol, power and enclosure

Quote confirmation

Model, quantity, certificates and delivery

Representative remote-monitoring integration with field enclosure, gateway, power and industrial equipment

Remote integration context

Representative site context. Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.

Select the radio region, probe and battery as one configuration

The reviewed single-product data sheet supports the values below. Reporting behavior, payload, ingress rating and documentation remain part of the ordered configuration.

  • The reviewed radio protocol is LoRaWAN 1.0.3. Supported regional plans include EU868, AU915, US915, AS923, IN865, KR920 and RU864; the ordered region is fixed before shipment.
  • Temperature accuracy is ±0.2 °C from 0 to 60 °C. Humidity accuracy is listed as a typical ±1.8%.
  • Built-in flash stores records while the network is unavailable and supports upload after connectivity is restored.
Show 3 more reviewed selection notes

Model-selection reference

Industrial Monitoring Hardware Catalog

Use this audited section to compare available hardware configurations. The representative website image is not an exact model photograph; the ordered configuration is confirmed in the quotation.

Open this catalog section
Catalog section
Wireless industrial temperature and humidity sensors
SG-coded options
14
PDF pages
6–8

Continue product selection

Compare adjacent hardware families for the same monitoring path. The final combination is checked against the project I/O, protocol, power and enclosure requirements.

How to choose

  • Use the reviewed LoRaWAN 1.0.3 path rather than treating generic LoRa and LoRaWAN as interchangeable; the logger, gateway and network server must share the selected regional plan.
  • Choose the internal-sensor or external-probe configuration from the monitored space, response requirement and cable placement.
  • Define the required accuracy, alarm thresholds and any calibration or traceability documents for cold-chain or controlled-environment use.
  • Set reporting, alarm and offline-recovery behavior from the required response time and battery-life target.
Show 2 more selection checks

Compatible with

  • LoRaWAN gateways and network servers using the selected EU868, AU915, US915, AS923, IN865, KR920 or RU864 regional plan
  • BLE 5.0 configuration from a compatible commissioning device
  • Cold-room, logistics, warehouse and equipment-room monitoring workflows that can use decoded temperature and humidity payloads
  • Customer platforms connected through the selected LoRaWAN network server after the payload format, decoder and delivery interface are confirmed

Typical package

  • LoRaWAN temperature and humidity data logger in the selected internal-sensor or external-probe configuration
  • One selected power version: 10,400 mAh replaceable battery, 2,200 mAh Ni-MH rechargeable battery or 4,000 mAh Li-Po rechargeable battery
  • Regional-frequency LoRaWAN gateway coverage and network-server access
  • Mounting, placement and environmental review for the monitored room, cabinet, shipment or outdoor point
  • Payload decoder, reporting interval, alarm thresholds and offline-data recovery acceptance test

Applications

Representative agricultural monitoring station with weather sensor, solar supply, field enclosure and soil probe
Representative field-monitoring context. Sensor set, mast, solar supply, enclosure and probe placement are selected for the crop and site.

Use this LoRaWAN data logger when a room, cabinet, shipment or remote site needs battery-powered temperature and humidity records without local Ethernet or cellular wiring. The reviewed device stores readings in built-in flash when the LoRaWAN path is unavailable and uploads them after connectivity returns. Select the regional radio plan, internal sensor or external probe, battery version, reporting interval and alarm behavior before quotation.

  • Cold-room, refrigerated-storage and transport temperature/humidity records
  • Equipment-room, cabinet and warehouse environmental monitoring
  • Remote indoor or outdoor points where battery power and LoRaWAN coverage are available
  • Local data retention during temporary gateway or network-server outages
  • Threshold alarms and trend data for operational monitoring, not regulated calibration or safety shutdown
See the full solution

What to include in your quote request

  • Target country and LoRaWAN regional plan
  • Internal sensor or external probe, including probe placement and cable
  • Temperature / humidity range, accuracy, alarms and required calibration documents
  • Sensor locations, gateway distance, walls and other obstructions
  • Reporting / alarm interval and offline-data recovery requirement
  • Replaceable or rechargeable battery preference and deployment-duration target
  • Gateway, network server, payload decoder and destination platform
  • Quantity, pilot acceptance criteria and project stage
Request a Quote

Related selection guides

Related resources

Frequently asked questions

Is this a LoRaWAN temperature and humidity data logger?

Yes. The reviewed device uses LoRaWAN 1.0.3 and supports EU868, AU915, US915, AS923, IN865, KR920 and RU864 regional plans. The project must select one compatible region across the logger, gateway and network server.

What measurement accuracy is supported by the reviewed data sheet?

Temperature accuracy is ±0.2 °C from 0 to 60 °C. Humidity accuracy is listed as a typical ±1.8%. For regulated cold-chain or calibration-controlled use, the required traceability and calibration documents must be specified separately.

What happens if the LoRaWAN connection is interrupted?

The reviewed logger has built-in flash storage. It can retain readings while the network is unavailable and upload the stored records after connectivity is restored. Storage capacity, reporting interval and recovery acceptance criteria are confirmed for the project.

Which battery version should I choose?

The reviewed versions use either a 10,400 mAh replaceable battery, a 2,200 mAh Ni-MH rechargeable battery or a 4,000 mAh Li-Po rechargeable battery. Choose from the deployment duration, reporting and alarm intervals, charging access and temperature conditions.

Is the published 7 km LoRa distance guaranteed at my site?

No. The source document lists up to 7 km in urban open space, not a guaranteed installed range. Buildings, terrain, antenna placement, regional settings and gateway height affect coverage, so the project uses a coverage review or pilot test.

Does every unit include the external probe shown in the representative image?

No. An external-probe version is available, but the ordered sensor configuration must be written into the quotation. The public image is representative and does not prove that a particular probe, cable or battery version is included.

What should I provide when requesting a quote for the LoRaWAN Temperature & Humidity Data Logger?

Target country and LoRaWAN regional plan; Internal sensor or external probe, including probe placement and cable; Temperature / humidity range, accuracy, alarms and required calibration documents; Sensor locations, gateway distance, walls and other obstructions

Where can I compare available model options?

Open the Industrial Monitoring Hardware Catalog linked on this page. It lists audited SG-coded selections; the ordered configuration is confirmed in the quotation.

Will it work with my existing system?

Compatibility is reviewed against your field signals, protocols and upstream platform. Typical pairings include LoRaWAN gateways and network servers using the selected EU868, AU915, US915, AS923, IN865, KR920 or RU864 regional plan, BLE 5.0 configuration from a compatible commissioning device, Cold-room, logistics, warehouse and equipment-room monitoring workflows that can use decoded temperature and humidity payloads.