SG-WQE-101: Dissolved Oxygen Sensor

Pictured: SG-WQE-101 — Dissolved Oxygen Sensor.

Optical Dissolved Oxygen Sensor for Water & Wastewater

Equipment options & specifications

Monitor dissolved oxygen in fish ponds and recirculating aquaculture tanks with a fluorescence optical probe. Choose Type A, B or C for the water, range and response required, then connect simultaneous RS485 Modbus RTU and 4–20 mA outputs to compatible receiving equipment.

Related application hardware: Farm water & pump monitoring

Choose a DO measurement point for your pond or tank

The useful measurement starts with the water and a probe that staff can reach. Plan the range, mounting and cleaning alongside the connection to your existing controller.

PondDO probeRecords

Fish ponds and freshwater aquaculture

Compare Type A for freshwater and general aquaculture duties with the range and response needed at the pond. Choose the measuring depth, bracket and cable route so the probe can be removed for cleaning. Give the normal and lowest expected readings when requesting a configuration.

  1. Selected pond depth and cleaning access
  2. Optical DO probe and field cable
  3. DO and temperature at logger or RTU
Quote a fish-pond DO probe →
TankDO probeRecords

Recirculating aquaculture tanks and existing controllers

State freshwater or saltwater conditions and the tank or pipe installation. Compare Type B and C for the required response and wetted materials. Match RS485 or analog inputs to the receiving controller. Alarm settings and any aerator control need their own controller and electrical design.

  1. Tank water and mounting conditions
  2. Selected probe and compatible input
  3. Monitoring, alerts or specified control
Quote a tank or controller connection →

Compare the probe types and installation

Type A
0–20 mg/L, ±0.3 mg/L, with T90 under 100 seconds. Compare this option for freshwater, aquaculture and similar general-water duties.
Types B and C
0–20 or 0–50 mg/L, ±0.2 mg/L, with T90 under 40 seconds. Match the wetted-material scope to the water chemistry and installation.
Controller and power
Simultaneous RS485 Modbus RTU and 4–20 mA; RS485 includes DO, saturation and temperature. Provide a compatible input and 7–28 VDC supply.
Mounting and maintenance
Select immersion or compatible pipe installation, the bracket or NPT3/4 hardware and cable length. Keep the fluorescent surface clean and clear of bubbles; include calibration checks and cap inspection.

What to send for a quotation

Send the site country, pond or tank count, freshwater or saltwater conditions, water temperature and expected DO readings. Include mounting depth or pipe conditions, cable length, controller input and available supply. Ask for the probe alone or a list of monitoring equipment.

Request a DO probe configuration for my water →

Which dissolved oxygen probe should I choose for a fish pond?

Start with the water chemistry, temperature, expected DO range, measuring depth and response required. Type A covers 0–20 mg/L; Types B and C add range and response options with different wetted-material scopes. Include the receiving controller and cleaning access in the equipment request.

Can I replace an existing 4–20 mA DO probe with this optical sensor?

Send the controller input specification, existing measurement range, supply, cable and mounting details. This sensor provides 4–20 mA and RS485 Modbus RTU simultaneously. Match the ordered range, scaling and installation before connecting it to the controller.

Match the DO probe to the pond, tank or water process

Follow dissolved oxygen in fish ponds, aquaculture tanks and recirculating water. Choose the probe for the required range and water conditions, with a measurement point that staff can reach for cleaning and calibration.

SG-WQE-115: Optical Dissolved Oxygen Sensor
Pictured: SG-WQE-115 — Optical Dissolved Oxygen Sensor.

Compare the optical DO probe types

Choose the range and response needed at the pond or tank. For types B and C, include the water chemistry and wetted-material requirements with your request.

Dissolved oxygen probe type ranges, accuracy and response times
Type ADO range0–20 mg/LAccuracy±0.3 mg/LT90 response<100 s
Type BDO range0–20 or 0–50 mg/LAccuracy±0.2 mg/LT90 response<40 s
Type CDO range0–20 or 0–50 mg/LAccuracy±0.2 mg/LT90 response<40 s

The probe provides RS485 Modbus RTU and 4–20 mA simultaneously, with a 7–28 VDC supply. Plan access for cleaning, air / zero calibration and fluorescent-cap inspection.

  1. DO probe
  2. PLC or logger
  3. Records / alerts
Example signal path. The receiving equipment, field power and any remote connection are selected for the site.

For a quotation, send the water type, normal and expected low oxygen levels, temperature, depth, controller input and number of ponds or tanks. Include a photo of the proposed measuring point.

  • State freshwater or saltwater conditions, temperature, measurement depth and required DO range.
  • Confirm the selected probe type, compensation settings and receiving RS485 or analog input.
  • Agree cleaning access, calibration checks and who responds to alarms; aeration control needs a separately defined design.
Get a DO probe quote for your ponds or tanks

Specifications & version options

Measurement principle
Fluorescence optical DO with temperature compensation
Type A range / accuracy
0–20 mg/L / ±0.3 mg/L
Type B / C range / accuracy
0–20 or 0–50 mg/L / ±0.2 mg/L
Resolution
0.01 mg/L DO; 0.1 °C temperature
Temperature channel
0–60 °C / ±0.5 °C via RS485
Response time
Type A T90 <100 s; Type B / C T90 <40 s
Show 6 more specification rows

Equipment quotation

The quotation lists the selected equipment, accessories, price and delivery terms.

Purchasing and delivery details →

Documents and downloads

Selection guidance and application documents. Wiring, register maps and certificates must match the chosen model and version.

Open family selection sheet

English · Web page · printable
Online selection guide

View application guide (PDF)

Application selection guide
PDF · English

Model-specific documents

Tell us which wiring, protocol or calibration documents you need for the equipment.

On this page
Application guide and product-family selection sheet
For your configuration
  • Exact-model datasheet
  • Wiring / pinout
  • Register map, protocol or sample data
  • Model-specific certificates
  • Calibration and measurement evidence
  • Dimensions / installation drawing
Project starter files →
Request an engineering package →
From a product family to your order
  1. Family page

    Compare uses, interfaces and configuration options. These are selection references.

  2. Equipment configuration

    Define the required function, interfaces, power, mounting and accessories for the site.

  3. Written quotation

    Confirm the exact model, configuration, photograph, document revisions, accessories, price, delivery and warranty.

Get selection help

Tell us what you want to measure and where. Send a model number or site photo if you have one.

Text stays in this tab for up to 30 minutes while you browse. Saving across reloads is optional below.

A personal email is welcome.

A country and general site description are enough. If the location is undecided, say so.

Photos, model information or BOM (optional)

Up to 5 files, 10 MB each. PDF, JPG, PNG, WebP, CSV, TXT, DOCX or XLSX.

By submitting this form, you acknowledge the privacy notice.

See where the system fits

Equipment in the system

Example equipment arrangement. Check compatibility and agree who handles software, PLC/SCADA programming and site installation.

SG-RTU-145: Water Level Telemetry Terminal

Product photograph

Pictured: SG-RTU-145 — Water Level Telemetry Terminal.

Choose the dissolved-oxygen type before quotation

Available configurations include three probe types with different range, accuracy, response and wetted-material scopes.

  • Type A covers 0–20 mg/L at ±0.3 mg/L with T90 under 100 seconds for freshwater, aquaculture and similar general-water duties.
  • Types B and C cover 0–20 or 0–50 mg/L at ±0.2 mg/L with T90 under 40 seconds; the wetted-material scope differs between the performance and anti-corrosion versions.
  • The electrical configuration provides RS485 Modbus RTU and 4-20 mA at the same time. RS485 data includes dissolved oxygen, saturation and temperature.
Show 3 more selection notes

Continue product selection

Compare related equipment and connection options.

How to choose

  • Select Type A, B or C from the water chemistry, 0–20 or 0–50 mg/L range, required ±0.3 or ±0.2 mg/L accuracy, response time and wetted-material requirement.
  • Use the simultaneous RS485 Modbus RTU and 4-20 mA outputs only after the receiving PLC, RTU or logger inputs, register map and 7–28 VDC supply have been checked.
  • Provide immersion depth or pipe geometry, NPT3/4 mounting, pressure, temperature, cable run, bubble risk and cleaning / calibration access.

Compatible with

  • PLC, RTU or water-quality controller accepting RS485 Modbus RTU and 4-20 mA
  • 4G or Ethernet telemetry gateways with a documented RS485 register map
  • Pipe or immersion installations within the pressure and temperature limits
  • Aquaculture, aeration-basin and surface-water monitoring points with planned cleaning and calibration access

Typical package

  • Selected Type A, B or C optical dissolved-oxygen probe
  • Standard 5 m field cable; other length stated in the quotation
  • Optional bracket or NPT3/4 pipe hardware selected for the installation
  • PLC, RTU, controller or telemetry gateway only when listed in the quotation
  • Register-map, wiring, calibration and maintenance notes for the ordered configuration

Applications

SG-EMF-102: Electromagnetic Flow Meter, Integrated and Remote
Pictured: SG-EMF-102 — Electromagnetic Flow Meter, Integrated and Remote.

Use this fluorescence optical probe for continuous dissolved-oxygen monitoring in aquaculture tanks, wastewater aeration basins, surface water and compatible process-water points. Select Type A, B or C from the required range, accuracy, response time, wetted materials and water chemistry; the variants are not interchangeable.

  • Aquaculture dissolved-oxygen monitoring with temperature compensation
  • Wastewater aeration-basin trend monitoring and alarm input
  • River, channel and surface-water dissolved-oxygen stations
  • RS485 or 4-20 mA measurement points connected to an existing PLC, RTU or logger
See related application hardware

Related selection guides

Related resources

Frequently asked questions

Which dissolved-oxygen range and accuracy should I order?

Type A is 0–20 mg/L at ±0.3 mg/L. Types B and C can be 0–20 or 0–50 mg/L at ±0.2 mg/L. Share the water type, expected normal and upset range, response requirement and corrosion conditions so the correct type can be quoted.

Does the probe provide both RS485 and 4-20 mA?

Yes. The electrical configuration provides RS485 Modbus RTU and 4-20 mA simultaneously. Confirm the PLC, RTU or logger input, register map, cable length and power arrangement before commissioning.

What calibration and maintenance does an optical DO sensor need?

The manual documents air and zero-oxygen calibration. Keep the fluorescent surface clean, prevent bubbles from remaining on it and inspect the fluorescent cap. Cap life depends on use and water conditions; it is not a maintenance-free item.

Can the dissolved-oxygen probe be used in a pipe or under water?

The scope supports pipe or immersion installation, IP68 protection, NPT3/4 upper and lower threads, operation from -5 to +60 °C and working pressure up to 0.8 MPa. The bracket, insertion arrangement and service access still need site review.

What do you need to select a dissolved oxygen sensor for a fish pond?

Send the freshwater or saltwater conditions, water temperature, normal and lowest expected oxygen readings, measurement depth and pond count. Add the cable length, receiving controller input and available supply. Include the cleaning and calibration access at each measurement point.

Will a dissolved oxygen sensor switch the pond aerator automatically?

The sensor provides a measurement to a compatible receiving input. Automatic aerator control also needs a controller, agreed thresholds, electrical interfaces and local protection. Specify monitoring, alerts and control as separate tasks in the equipment request.

Will it work with my existing system?

Use the listed inputs, power and protocol to match the device to your controller. Send its model or an input photo with the equipment request.