Water Quality Sensors: pH, EC and Dissolved Oxygen

Product overview with English on-screen explanations. No audio. Read the chapter summary below.

Start with the water and the reading you need. Irrigation water, a nutrient tank and a fish pond call for different measurements. This range uses separate probes for pH, conductivity and dissolved oxygen, with RS485 Modbus RTU for the receiving logger or controller.

Compare the equipment and connections

pH probe

0.00–14.00 pH; ±0.02 pH accuracy; 0.01 pH resolution.

For acidity readings in water or nutrient tanks. Glass electrode; operating temperature 0–100°C.

Conductivity / TDS probe

EC: 0–500.00 mS/cm. TDS: 0–320,000.0 mg/L. Accuracy: ±1% of reading.

For conductivity trends in irrigation or process water. Graphite electrode; operating temperature 0–50°C.

Membrane dissolved-oxygen probe

0–20 mg/L and 0–200%. Accuracy: ±0.2 mg/L at 0–8 mg/L; ±0.3 mg/L at 8–20 mg/L.

For ponds and tanks. Membrane electrode; operating temperature 0–40°C. Include membrane care and access in the installation plan.

Connection and service

RS485 Modbus RTU and a Wi-Fi browser interface. 9–36 VDC for the version without air-pump cleaning.

These Taiwan-made probes have an IP68 housing. The browser interface provides calibration access; the logger and network provide the site data connection.

Cleaning option

24 VDC air pump and nozzle option; 6.8 W listed consumption with cleaning, compared with 0.8 W without it.

Specify cleaning, cable length, connector and mounting arrangement with the quotation. Cleaning does not replace calibration or electrode maintenance.

  • The video shows the pH probe appearance. The three measurements use separate probes; it is not a single multiparameter probe.
  • The specifications above describe this browser-calibrated instrument range. Other water-sensor families have different ranges and service requirements.
  • Choose immersion, tee or insertion mounting to suit the water path. Keep the probe accessible for cleaning, calibration and replacement.

Video chapters

  1. 0:00

    Choose the reading first

    pH, conductivity and dissolved oxygen measure different water conditions. Choose separate probes for the readings you need.

  2. 0:08

    pH for water monitoring

    Check the acidity of irrigation, nutrient or process water. RS485 Modbus RTU connects to a matching logger.

  3. 0:16

    Conductivity and TDS

    Use EC to follow changes in dissolved ions. Match the range and temperature to the water at the measurement point.

  4. 0:24

    Dissolved oxygen

    For ponds and water tanks, measure oxygen alongside the water temperature. Choose the probe type and maintenance plan together.

  5. 0:32

    Keep calibration accessible

    Browser calibration is available on the instruments in this range. Air-pump cleaning is a separate option.

  6. 0:40

    Build your equipment list

    Send the water type, measurement points, required readings and logger interface.

Specifications and application planning

Send the details for your equipment list

Include a drawing, equipment list or a brief description of the site. These details help us match the instruments and connections.

  • Water type and normal temperature
  • Readings, expected range and number of points
  • Immersion or pipe mounting, and cable length
  • Logger interface, supply and cleaning requirements