Crop light · PAR · RS485 output

RS485 PAR Quantum Sensor for Greenhouses and Crops

Measure photosynthetically active light across 400–700 nm, with a 0–2,500 µmol/m²/s range and RS485 output. 12 VDC supply, IP68 housing and a 3 m cable.

Par quantum light sensor: Soil / crop point → Sensor output → Local collection → Customer records.
Par quantum light sensor — connection diagram.

Measure plant-light conditions at the crop or greenhouse monitoring point. This quantum sensor covers the 400–700 nm PAR band and reports a reading in µmol/m²/s. Its aluminum housing and mounting flange provide a fixed sensor position for the light record.

Agricultural uses and site planning

SG-WS-132: Atmospheric Temperature and Humidity Sensor
Pictured: SG-WS-132 — Atmospheric Temperature and Humidity Sensor.

Greenhouse light records

Record PAR at the selected growing-area position alongside greenhouse temperature and humidity.

SG-SRD-113: PAR (Photosynthetically Active Radiation) Quantum Sensor
Pictured: SG-SRD-113 — PAR (Photosynthetically Active Radiation) Quantum Sensor.

Crop light monitoring

Use a fixed measuring position to collect light readings for the crop area.

Farm monitoring site plan: Measurement point → Available output → Logger or gateway → Customer system.
Farm monitoring site plan — connection diagram.

Separate PAR and illuminance channels

Use the quantum sensor for the PAR reading and an illuminance sensor for a separate lux reading.

Send the details for your equipment list

Include these details with your inquiry so the equipment and options match your site.

  • Greenhouse or crop monitoring position
  • Point count and destination country
  • Cable length and connector
  • Receiving logger or controller and 12 VDC supply

Choose the configuration

Cable connection

3 m bare-wire cable or 3 m cable with a quick connector. Cable length and connector belong to the selected arrangement.

Power and data

12 VDC supply and an RS485 output. Include the receiving logger or controller details in the equipment request.

Fixed measuring point

The circular mounting flange holds the sensor at its selected light-measurement position.

Specifications

RS485 PAR Quantum Sensor for Greenhouses and Crops specifications
ItemSpecification
Spectral range400–700 nm
Measurement range0–2,500 µmol/m²/s
OutputRS485
Power supply12 VDC
Accuracy±(5% of reading + 10 digits)
Linearity±2%
Response time<5 seconds
Cosine response≤±10%
Operating environment-40 to 80 °C; 0–100% RH
HousingAluminum alloy
ProtectionIP68
Standard cable3 m; bare-wire or quick-connector end
  • PAR readings use µmol/m²/s. Illuminance readings use lux; they are separate measurements.

Questions about this equipment

Is this the same measurement as lux?

This sensor measures the 400–700 nm PAR band and provides a photon-flux reading in µmol/m²/s. A lux sensor supplies a separate illuminance reading.

What are the measuring range and output?

The measuring range is 0–2,500 µmol/m²/s and the output is RS485.

What power and cable arrangement does it use?

The sensor uses 12 VDC and a standard 3 m cable, with a bare-wire or quick-connector end.