Skip to content
SunGeneAgricultural IoT
← Agricultural equipment

Wind speed · Wind direction · Separate or combined mounting

RS485 Cup Anemometer & Wind Vane: 0–70 m/s

Build a wind measurement point from a cup anemometer, a wind vane, or both on a combined mounting. Each measurement uses RS485 Modbus RTU. The address and baud rate can be set for the connected logger or controller.

Cup anemometer for RS485 wind-speed measurement
Cup anemometer for wind-speed measurement.

Choose the configuration

Wind speed

Cup anemometer with a 0–70 m/s range.

Wind direction

Wind vane covering 360°.

Combined mounting

Wind speed and direction on one mounting arrangement. Bare-wire or quick-connector ends; 100 or 150 cm mounting-band lengths are available.

Specifications

RS485 Cup Anemometer & Wind Vane: 0–70 m/s specifications
ItemSpecification
CommunicationRS485 Modbus RTU; configurable address and baud rate
Power supply12–24 VDC
Wind-speed range0–70 m/s
Wind-speed accuracy±0.3 m/s or ±0.5% full scale
Wind-speed resolution0.1 m/s
Wind direction360°; accuracy ±3°; resolution 1°
Power consumption≤0.48 W per sensor
MaterialUV-resistant ABS
Operating conditions-35 to 60 °C; 0–100% RH, non-condensing; IP64
Standard cable2.5 m
Wind-speed rotation diameter180 mm
Wind-direction rotation diameter295 mm
  • Select wind speed, wind direction or the combined arrangement from the required measurement list.
  • Set the wind-direction reference to north during installation.

Where it fits

Farm weather measurements

Add wind speed, direction or both to a facility-agriculture weather point.

Existing RS485 logger

Use the configured device address and baud rate to bring wind readings into the station record.

Outdoor site monitoring

Measure local wind for environmental, weather and wind-power monitoring installations.

Wind vane for RS485 wind-direction measurement
Wind-direction vane.

Send the details for your equipment list

Include these details with your inquiry so the equipment and options match your site.

  • Wind speed, wind direction or both
  • Separate or combined mounting
  • Bare-wire or quick connector and clamp size
  • Point count, logger interface and destination country

Questions about this equipment

Can I order only wind speed or only direction?

Wind-speed, wind-direction and combined arrangements are available. Select the measurements the site needs.

Can the RS485 settings be changed?

The device address and baud rate can be set for the connected Modbus RTU system.

What mounting and cable options are listed?

The standard cable is 2.5 m. Bare-wire and quick-connector ends are available, with no clamp or a mounting band measuring 100 or 150 cm in length.

Connections and related equipment

The equipment list brings together the sensing or control points, supply, wiring, data connection and installation work.