4, 8 or 16 relay points
Choose the control-point count. A four-point version with intermediate relays supports live L/N output.
4 / 8 / 16 relay points · Local manual operation · Web-configured schedules and logic
Group local switching, schedules and sensor-based control in one panel. Configure time periods, value-linked actions, alternating operation, interlocks or greenhouse screen extension and retraction through the web interface. Stored logic runs locally without a network connection.

Choose the control-point count. A four-point version with intermediate relays supports live L/N output.
UV-resistant ABS, powder-coated galvanized steel or 304 stainless steel. IP67 is listed for the ABS enclosure.
Ethernet or Wi-Fi, with optional 4G or 4G/video transmission. Load-current detection uses an optional current sensor.
| Item | Specification |
|---|---|
| Power supply | 110/220 VAC, 50/60 Hz |
| Listed power consumption | 100 W |
| Control points | 4, 8 or 16 |
| Dry-contact rating | Current <1 A; maximum voltage 250 VAC |
| Serial interface | 1 × RS485, Modbus RTU |
| Ethernet interface | RJ45; Web Service and Modbus TCP |
| Network | Ethernet or Wi-Fi; optional 4G |
| Local logic | Schedules, value-linked actions, alternating operation, interlocks and greenhouse screen control |
| ABS enclosure | UV-resistant ABS; IP67; 300 × 400 × 190 mm; <6 kg |
| 4-point metal enclosure | Powder-coated galvanized steel or 304 stainless steel; 430 × 600 × 210 mm; <25 kg |
| 8/16-point metal enclosure | Powder-coated galvanized steel or 304 stainless steel; 600 × 800 × 218 mm; <38 kg |
| Current monitoring | Optional external current sensor |
Configure screen extension/retraction, time schedules, sensor-value actions and software interlocks.
Use the alternating-operation function for a defined equipment sequence.
Combine local switches and configured logic for plant factories, livestock facilities, aquaculture and building equipment.
Include these details with your inquiry so the equipment and options match your site.
Stored logic executes locally without a network connection. The panel also provides local manual control.
Load-current detection uses an optional current sensor. 4G and 4G/video transmission are separate network options.
IP67 is listed for the UV-resistant ABS enclosure. The metal enclosure options have separate dimensions and weights.
Send the equipment list, relay-point count, required logic, enclosure material, supply and network arrangement, and the destination country.
The equipment list brings together the sensing or control points, supply, wiring, data connection and installation work.