Skip to content
SunGene Industrial Remote Monitoring HardwareSunGeneIndustrial hardware
Back to product
SunGene Industrial IoT
SunGene
Industrial IoT
Product Datasheet
Ultrasonic Weather Station

Ultrasonic Weather Station

Configurable 5-, 6- or 9-channel weather instrument with mandatory ultrasonic wind measurement and a selected RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12 interface.

Category: Environmental & Agriculture Sensors

Representative image

Representative ultrasonic weather-instrument visual derived from reviewed exact-model documents and independently de-identified. It is not the final ordered-model photograph; channel set, output, protocol, heater, positioning functions, cable, mounting, markings and certificates are confirmed in the quotation.

Specifications

Channel sets5, 6 or 9 channels; wind speed and direction are mandatory
Five-channel setWind speed, wind direction, air temperature, relative humidity and atmospheric pressure
Optional channelsPrecipitation; on the reviewed 9-channel set: solar radiation, illuminance and dust
Wind speed0–60 m/s; 0.01 m/s resolution; ±2% FS accuracy
Wind direction0–360°; 1° resolution; <3° accuracy
Air temperature-40 to +80 °C; ±0.5 °C accuracy
Humidity / pressure0–100% RH at ±3% RH; 300–1100 hPa at ±1 hPa
Output optionsOne selected interface: RS485, RS232 or SDI-12
Protocol optionsModbus RTU (default reviewed RS485 path), NMEA-0183 or SDI-12
Power supply12–24 VDC
Power budget<3 W base instrument; optional heater and added modules sized separately
Update cycle1 second default; other cycles by configuration
Protection / climateIP66; -40 to +80 °C operating range
ConstructionASA main body; optional aluminium-alloy base
Mobile-platform optionsGPS / BDS and electronic compass are optional

Select the channels and interface before treating this as one weather station

The reviewed documents describe a configurable instrument family, not one universal all-channel configuration.

  • Wind speed and wind direction are mandatory. The five-channel set adds air temperature, relative humidity and atmospheric pressure; the six-channel set adds precipitation; the nine-channel set adds precipitation, solar radiation, illuminance and dust.
  • RS485, RS232 and SDI-12 are alternatives, not simultaneous standard outputs. Modbus RTU is the default reviewed protocol for RS485; NMEA-0183 and SDI-12 require their matching ordered interface.
  • The base instrument is below 3 W in the reviewed documents. Optional ultrasonic-head heating and added sensor modules change the site power budget and must be sized separately.
  • IP66 protects the instrument enclosure, but it does not remove the need for correct siting, mast rigidity, grounding, lightning / surge protection, obstruction clearance and periodic inspection.
  • The page does not claim a regulatory-reference meteorological station. Project accuracy, calibration documents and acceptance criteria are confirmed for the intended use before quotation.

Typical applications

  • Unattended agricultural, environmental and field-weather monitoring stations
  • Solar- and wind-site operating-condition monitoring linked to a customer logger, RTU or SCADA system
  • Traffic, port, vessel or mobile-platform projects after positioning, orientation and mounting are reviewed
  • Compact weather inputs for customer-owned data platforms where a selected serial protocol is already defined

Inquiries: contact@sungeneiot.com · sungeneiot.com

Specifications are for reference and may be updated; confirm the final spec with SunGene before ordering.