SunGene
Agricultural IoT
Product Family Selection Sheet

Ultrasonic Weather Station
Configurable 5-, 6- or 9-channel weather instrument with mandatory ultrasonic wind measurement and a selected RS485 Modbus RTU, RS232 NMEA-0183 or SDI-12 interface.
Category: Environmental & Agriculture Sensors
Pictured: SG-WS-163 — Ultrasonic Automatic Weather Station.
Specifications & version options
| Channel sets | 5, 6 or 9 channels; wind speed and direction are mandatory |
|---|---|
| Five-channel set | Wind speed, wind direction, air temperature, relative humidity and atmospheric pressure |
| Optional channels | Precipitation; on the 9-channel set: solar radiation, illuminance and dust |
| Wind speed | 0–60 m/s; 0.01 m/s resolution; ±2% FS accuracy |
| Wind direction | 0–360°; 1° resolution; <3° accuracy |
| Air temperature | -40 to +80 °C; ±0.5 °C accuracy |
| Humidity / pressure | 0–100% RH at ±3% RH; 300–1100 hPa at ±1 hPa |
| Output options | One selected interface: RS485, RS232 or SDI-12 |
| Protocol options | Modbus RTU (default RS485 protocol), NMEA-0183 or SDI-12 |
| Power supply | 12–24 VDC |
| Power budget | <3 W base instrument; optional heater and added modules sized separately |
| Update cycle | 1 second default; other cycles by configuration |
| Protection / climate | IP66; -40 to +80 °C operating range |
| Construction | ASA main body; optional aluminium-alloy base |
| Mobile-platform options | GPS / BDS and electronic compass are optional |
Select the channels and interface before treating this as one weather station
The instrument is configured with selected measurement channels. The quotation lists the installed modules.
- Wind speed and wind direction are mandatory. The five-channel set adds air temperature, relative humidity and atmospheric pressure; the six-channel set adds precipitation; the nine-channel set adds precipitation, solar radiation, illuminance and dust.
- RS485, RS232 and SDI-12 are alternatives, not simultaneous standard outputs. Modbus RTU is the default protocol for RS485; NMEA-0183 and SDI-12 require their matching ordered interface.
- The base instrument is below 3 W in the product documentation. Optional ultrasonic-head heating and added sensor modules change the site power budget and must be sized separately.
- IP66 protects the instrument enclosure, but it does not remove the need for correct siting, mast rigidity, grounding, lightning / surge protection, obstruction clearance and periodic inspection.
- For regulatory-reference measurements, confirm that the selected instrument, calibration documents and test criteria meet the intended use. A monitoring configuration alone does not establish regulatory suitability.
Typical applications
- Unattended agricultural, environmental and field-weather monitoring stations
- Orchard and nursery operating-condition monitoring linked to a compatible customer logger, RTU or SCADA system
- Field and orchard weather points after positioning, orientation and mounting are reviewed
- Compact weather inputs for customer-owned data platforms where a selected serial protocol is already defined
Inquiries: contact@sungeneiot.com · sungeneiot.com
Select the required measurements and connection options from this sheet. Include the quantity, destination and accessories in your equipment request.