Skip to content
SunGene Industrial Remote Monitoring HardwareSunGeneIndustrial hardware
Back to product
SunGene Industrial IoT
SunGene
Industrial IoT
Product Datasheet
Water Conductivity (EC) Sensor

Water Conductivity (EC) Sensor

Online EC probe family with selectable materials and ranges, ±1% FS accuracy, and simultaneous 4-20 mA plus RS485 Modbus RTU output.

Category: Water & Wastewater Instrumentation

Representative image

Representative online conductivity-probe visual interpreted from a reviewed exact-model reference and independently de-identified. It is not an exact product photograph; Type A/B/C/D construction, range, pressure, temperature, process connection, cable, output, markings and certificates are confirmed in the quotation.

Specifications

Measured propertyOnline electrical conductivity (EC)
Type A / B ranges0–2000 / 5000 / 10000 / 20000 µS/cm
Type C ranges0–2000 / 5000 / 10000 / 20000 µS/cm; reviewed custom ranges available
Type D ranges0–50 / 500 / 10000 / 20000 µS/cm
Accuracy / resolution±1% FS; 0.01 mS/cm
Outputs4-20 mA and RS485 Modbus RTU simultaneously; Type D two-wire 4-20 mA optional
Supply7–30 VDC; Type D two-wire 4-20 mA configuration 22–28 VDC
Response / drift1 s response; ≤0.3% FS per 24 h drift
Power<0.2 W
Temperature compensation0–60 °C on Types A/B/C; Type D configuration up to 0–100 °C
MaterialsType A ABS/graphite; Type B nylon fibre/316; Type C nylon fibre/graphite; Type D 316L/PEEK
PressureType A 0.8 MPa; Types B/C 1.0 MPa; Type D 2.0 MPa
InstallationImmersion or NPT3/4 process connection, depending on type
Environment / cableProbe IP68; 5 m reviewed default cable

Choose the probe type from the medium, pressure and temperature

The four mechanical families do not share the same wetted materials or service limits.

  • Type A uses an ABS body with graphite electrodes and is reviewed to 0.8 MPa. Type B uses nylon fibre with 316 stainless steel; Type C uses nylon fibre with graphite. Types B and C are reviewed to 1.0 MPa.
  • Type D uses 316L and PEEK wetted materials, supports the reviewed high-temperature configuration and is reviewed to 2.0 MPa. Confirm whether the installation uses the Type D two-wire 4-20 mA option or the standard simultaneous-output configuration.
  • Select a documented range. Types A/B/C support 0-2000, 0-5000, 0-10000 or 0-20000 µS/cm; Type C also supports reviewed custom ranges. Type D supports 0-50, 0-500, 0-10000 or 0-20000 µS/cm.
  • Install the conductivity cell where it remains wetted and where bubbles do not collect across the measurement opening. Confirm immersion depth or NPT3/4 process geometry before release.
  • The probe is not maintenance-free: deposits, oil, biofilm and scale change the cell response. Define cleaning access, inspection frequency and the reference solution or comparison method.
  • IP68 applies to the probe. Cable entries, junctions, controllers and enclosures require their own environmental protection.
  • A matching manual documents calculated TDS and salinity data, but the direct measurement is EC. Confirm the ordered firmware/register set, conversion, units, temperature basis and acceptance method before using either derived value.

Typical applications

  • Freshwater, aquaculture and surface-water conductivity trend monitoring
  • Wastewater and process-water monitoring after wetted-material and fouling review
  • Pipe or tank installations using simultaneous analog and Modbus signals
  • Higher-temperature or higher-pressure service using the selected Type D configuration

Inquiries: contact@sungeneiot.com · sungeneiot.com

Specifications are for reference and may be updated; confirm the final spec with SunGene before ordering.