Skip to content
SunGeneAgricultural IoT
← Back to product
SunGene
Agricultural IoT
Product Family Selection Sheet
SG-WQE-106: Online Conductivity, Salinity and TDS Sensor

Water Conductivity (EC) Sensor

Online EC probe family with selectable materials and ranges, ±1% FS accuracy, and simultaneous 4-20 mA plus RS485 Modbus RTU output.

Category: Water & Wastewater Instrumentation

Pictured: SG-WQE-106 — Online Conductivity, Salinity and TDS Sensor.

Specifications & version options

Measured propertyOnline electrical conductivity (EC)
Type A / B ranges0–2000 / 5000 / 10000 / 20000 µS/cm
Type C ranges0–2000 / 5000 / 10000 / 20000 µS/cm; custom ranges confirmed per order
Type D ranges0–50 / 500 / 10000 / 20000 µS/cm
Accuracy / resolution±1% FS; 0.01 mS/cm
Outputs4-20 mA and RS485 Modbus RTU simultaneously; Type D two-wire 4-20 mA optional
Supply7–30 VDC; Type D two-wire 4-20 mA configuration 22–28 VDC
Response / drift1 s response; ≤0.3% FS per 24 h drift
Power<0.2 W
Temperature compensation0–60 °C on Types A/B/C; Type D configuration up to 0–100 °C
MaterialsType A ABS/graphite; Type B nylon fibre/316; Type C nylon fibre/graphite; Type D 316L/PEEK
PressureType A 0.8 MPa; Types B/C 1.0 MPa; Type D 2.0 MPa
InstallationImmersion or NPT3/4 process connection, depending on type
Environment / cableProbe IP68; standard 5 m cable

Choose the probe type from the medium, pressure and temperature

The four mechanical families do not share the same wetted materials or service limits.

  • Type A uses an ABS body with graphite electrodes and is rated to 0.8 MPa. Type B uses nylon fibre with 316 stainless steel; Type C uses nylon fibre with graphite. Types B and C are rated to 1.0 MPa.
  • Type D uses 316L and PEEK wetted materials, supports the high-temperature configuration and is rated to 2.0 MPa. Confirm whether the installation uses the Type D two-wire 4-20 mA option or the standard simultaneous-output configuration.
  • Select a documented range. Types A/B/C support 0-2000, 0-5000, 0-10000 or 0-20000 µS/cm; Type C also supports custom ranges confirmed for the order. Type D supports 0-50, 0-500, 0-10000 or 0-20000 µS/cm.
  • Install the conductivity cell where it remains wetted and where bubbles do not collect across the measurement opening. Confirm immersion depth or NPT3/4 process geometry before ordering.
  • The probe is not maintenance-free: deposits, oil, biofilm and scale change the cell response. Define cleaning access, inspection frequency and the reference solution or comparison method.
  • IP68 applies to the probe. Cable entries, junctions, controllers and enclosures require their own environmental protection.
  • A matching manual documents calculated TDS and salinity data, but the direct measurement is EC. Confirm the ordered firmware/register set, conversion, units, temperature basis and acceptance method before using either derived value.

Typical applications

  • Freshwater, aquaculture and surface-water conductivity trend monitoring
  • Wastewater and process-water monitoring after wetted-material and fouling review
  • Pipe or tank installations using simultaneous analog and Modbus signals
  • Higher-temperature or higher-pressure service using the selected Type D configuration

Inquiries: contact@sungeneiot.com · sungeneiot.com

Select the required measurements and connection options from this sheet. Include the quantity, destination and accessories in your equipment request.