Ultrasonic Water Level Sensor
Integrated non-contact liquid-level transmitter with selectable 5 to 30 m ranges and 4-20 mA or RS485 Modbus RTU output.
Category: Water & Wastewater Instrumentation
Representative image
Representative integrated ultrasonic level-transmitter visual derived from a reviewed exact-model reference and independently de-identified. It is not the final ordered-model photograph; range, blind zone, output, relay, power, process connection, display, markings and certificates are confirmed in the quotation.
Specifications
| Measurement | Non-contact ultrasonic liquid level |
|---|---|
| Range options | 5 / 10 / 15 / 20 / 30 m |
| Output options | 2-wire or 4-wire 4-20 mA; 4-wire RS485 Modbus RTU |
| Supply options | 24 VDC or 220 VAC; 12 VDC on the RS485 configuration only |
| Accuracy | 0.5-1% |
| Resolution | ±3 mm or 0.1% FS, whichever is greater |
| Display | LCD with English menu |
| Ingress protection | Probe IP68; display unit IP66 |
| Temperature | Probe -20 to +80 °C; display unit -20 to +60 °C |
| Process connection | Range-dependent threaded connection; confirm before quotation |
| Blind zone | Range-dependent; confirm against maximum liquid level |
Check the echo path before selecting ultrasonic level measurement
The reviewed specification supports an integrated non-contact transmitter, but site conditions determine whether the echo will remain stable.
- Choose a 5, 10, 15, 20 or 30 m configuration. The blind zone and threaded process connection change with the selected range.
- Mount the sensor axis perpendicular to the liquid surface and keep pipes, braces, ribs, ladders and mixing equipment outside the acoustic beam.
- Foam, bubbles, mist, steam, turbulence and strong temperature gradients can weaken or distort the return echo.
- Keep the maximum liquid level below the configured blind zone. A stilling arrangement can help only after its dimensions and opening are reviewed.
- Use a sun shield or enclosure where direct sunlight or large temperature changes can heat the display housing.
- Select radar, hydrostatic or another method when foam or site geometry makes ultrasonic measurement unreliable.
Typical applications
- Remote tank and reservoir level monitoring with a clear liquid surface
- Water-storage, irrigation and well-head installations where top mounting is practical
- Open-channel or river-level projects after the mounting geometry and echo path are reviewed
- PLC, SCADA or telemetry projects using 4-20 mA or RS485 Modbus RTU
Inquiries: contact@sungeneiot.com · sungeneiot.com