ISO 9060:2018 Class C thermopile pyranometer for 0–2000 W/m² global solar irradiance, with the output configuration selected for the site logger or RTU.

Category: Environmental & Agriculture Sensors

Appearance, connectors and accessories are confirmed with the ordered configuration.

Specifications & version options

Instrument classISO 9060:2018 Class C
Measurement range0–2000 W/m² global solar irradiance
Spectral range300–3200 nm
Sensitivity7–14 µV/(W/m²)
Non-linearity<±3%
Response time≤60 s to 95%
Zero drift±8 W/m² at a 5 K/h temperature change
Annual stability<±3% per year
Directional response≤±30 W/m²
Temperature effect<8% from -10 to +40 °C
Output variants0–20 mV passive, 4–20 mA, 0–5 V, RS485 Modbus RTU or SDI-12; one selected when ordering
SupplyNone for passive 0–20 mV; 5 VDC or 12–24 VDC depending on selected powered output
Environment-40 to +80 °C; IP67
BodyØ185 × 120 mm; 1.2 kg
CalibrationISO 9847 basis; two-year recalibration interval

SG codes for enquiry

12 sourcing references from “Solar radiation, PAR and light sensors”. Put an SG code in the RFQ so we can match the same catalog row.

  • SG-SRD-113
  • SG-SRD-110
  • SG-SRD-114
  • SG-SRD-115
  • SG-SRD-116
  • SG-SRD-117
  • SG-WS-137
  • SG-WS-133
  • SG-WS-152
  • SG-WS-145
  • SG-SRD-118
  • SG-SRD-119
Open this catalog section

Select the output, supply and mounting scope together

The reviewed Class C documents support the performance values below. Output, supply, cable, mounting and calibration deliverables remain order-specific.

  • The reviewed instrument classification is ISO 9060:2018 Class C, with a 0-2000 W/m² range and 300-3200 nm spectral response.
  • Sensitivity is 7-14 µV/(W/m²). Non-linearity is below ±3%, response time is no more than 60 seconds to 95%, and annual stability is below ±3% per year.
  • Performance is expressed through the Class C component specifications rather than one generic accuracy number.
  • Order one output configuration. Passive 0-20 mV needs no external supply; powered 4-20 mA, 0-5 V, RS485 Modbus RTU and SDI-12 versions use the supply defined for that ordered output.
  • The reviewed operating range is -40 to +80 °C with IP67 protection. Final cable, connector, mounting bracket and surge-protection scope are confirmed for the installation.
  • The reviewed calibration basis is ISO 9847, with a two-year recalibration interval. The quotation must state whether a calibration report or other traceability document is included.

Typical applications

  • PV plant reference irradiance and performance-ratio input
  • Automatic weather-station global solar-radiation measurement
  • Agricultural evapotranspiration and irrigation-support datasets
  • Solar-resource assessment and environmental monitoring
  • Remote irradiance logging through a selected RTU, logger or acquisition gateway