SG-SRD-114: Class C Pyranometer

Class C Pyranometer for Solar Radiation Monitoring

ISO 9060:2018 Class C thermopile pyranometer for 0–2000 W/m² global solar irradiance, with the output configuration selected for the site logger or RTU.

Category: Environmental & Agriculture Sensors

Pictured: SG-SRD-114 — Class C Pyranometer.

Specifications & version options

Instrument classISO 9060:2018 Class C
Measurement range0–2000 W/m² global solar irradiance
Spectral range300–3200 nm
Sensitivity7–14 µV/(W/m²)
Non-linearity<±3%
Response time≤60 s to 95%
Zero drift±8 W/m² at a 5 K/h temperature change
Annual stability<±3% per year
Directional response≤±30 W/m²
Temperature effect<8% from -10 to +40 °C
Output variants0–20 mV passive, 4–20 mA, 0–5 V, RS485 Modbus RTU or SDI-12; one selected when ordering
SupplyNone for passive 0–20 mV; 5 VDC or 12–24 VDC depending on selected powered output
Environment-40 to +80 °C; IP67
BodyØ185 × 120 mm; 1.2 kg
CalibrationISO 9847 basis; two-year recalibration interval

Select the output, supply and mounting scope together

Check the performance values below against your measurement requirements. Output, supply, cable, mounting and calibration documents are selected for the order.

  • The instrument classification is ISO 9060:2018 Class C, with a 0-2000 W/m² range and 300-3200 nm spectral response.
  • Sensitivity is 7-14 µV/(W/m²). Non-linearity is below ±3%, response time is no more than 60 seconds to 95%, and annual stability is below ±3% per year.
  • Performance is expressed through the Class C component specifications rather than one generic accuracy number.
  • Order one output configuration. Passive 0-20 mV needs no external supply; powered 4-20 mA, 0-5 V, RS485 Modbus RTU and SDI-12 versions use the supply defined for that ordered output.
  • The operating range is -40 to +80 °C with IP67 protection. Final cable, connector, mounting bracket and surge-protection scope are confirmed for the installation.
  • The calibration basis is ISO 9847, with a two-year recalibration interval. The quotation must state whether a calibration report or other traceability document is included.

Typical applications

  • Solar-irradiance records at farm weather stations
  • Automatic weather-station global solar-radiation measurement
  • Agricultural evapotranspiration and irrigation-support datasets
  • Nursery, field-research and agricultural environmental monitoring
  • Remote irradiance logging through a selected RTU, logger or acquisition gateway

Inquiries: contact@sungeneiot.com · sungeneiot.com

Select the required measurements and connection options from this sheet. Include the quantity, destination and accessories in your equipment request.