Class C Pyranometer for Solar Radiation Monitoring
ISO 9060:2018 Class C thermopile pyranometer for 0–2000 W/m² global solar irradiance, with the output configuration selected for the site logger or RTU.
Category: Environmental & Agriculture Sensors
Representative image
Representative Class C pyranometer visual interpreted from reviewed exact-model documents and reference imagery, then independently de-identified. It is not the final ordered-model photograph; instrument class, output, supply, cable, bracket, calibration documentation, markings and certificates are confirmed in the quotation.
Specifications
| Instrument class | ISO 9060:2018 Class C |
|---|---|
| Measurement range | 0–2000 W/m² global solar irradiance |
| Spectral range | 300–3200 nm |
| Sensitivity | 7–14 µV/(W/m²) |
| Non-linearity | <±3% |
| Response time | ≤60 s to 95% |
| Zero drift | ±8 W/m² at a 5 K/h temperature change |
| Annual stability | <±3% per year |
| Directional response | ≤±30 W/m² |
| Temperature effect | <8% from -10 to +40 °C |
| Output variants | 0–20 mV passive, 4–20 mA, 0–5 V, RS485 Modbus RTU or SDI-12; one selected when ordering |
| Supply | None for passive 0–20 mV; 5 VDC or 12–24 VDC depending on selected powered output |
| Environment | -40 to +80 °C; IP67 |
| Body | Ø185 × 120 mm; 1.2 kg |
| Calibration | ISO 9847 basis; two-year recalibration interval |
Select the output, supply and mounting scope together
The reviewed Class C documents support the performance values below. Output, supply, cable, mounting and calibration deliverables remain order-specific.
- The reviewed instrument classification is ISO 9060:2018 Class C, with a 0-2000 W/m² range and 300-3200 nm spectral response.
- Sensitivity is 7-14 µV/(W/m²). Non-linearity is below ±3%, response time is no more than 60 seconds to 95%, and annual stability is below ±3% per year.
- Performance is expressed through the Class C component specifications rather than one generic accuracy number.
- Order one output configuration. Passive 0-20 mV needs no external supply; powered 4-20 mA, 0-5 V, RS485 Modbus RTU and SDI-12 versions use the supply defined for that ordered output.
- The reviewed operating range is -40 to +80 °C with IP67 protection. Final cable, connector, mounting bracket and surge-protection scope are confirmed for the installation.
- The reviewed calibration basis is ISO 9847, with a two-year recalibration interval. The quotation must state whether a calibration report or other traceability document is included.
Typical applications
- PV plant reference irradiance and performance-ratio input
- Automatic weather-station global solar-radiation measurement
- Agricultural evapotranspiration and irrigation-support datasets
- Solar-resource assessment and environmental monitoring
- Remote irradiance logging through a selected RTU, logger or acquisition gateway
Inquiries: contact@sungeneiot.com · sungeneiot.com