Flow meter selection

Portable clamp-on flow meters: what to check before moving sites

Measure flow without cutting the pipe, then check whether the same kit will work at the next water point.

Portable clamp-on flow meters: what to check before moving sites

Can one portable clamp-on ultrasonic flow meter be used at different pump sites?

Yes, where each site falls within the selected meter and transducer limits. Review the pipe dimensions, material, liquid and accessible mounting position at every site. Moving the kit also means checking its setup again. A successful reading on one pipe does not establish compatibility with the next.

Plan the measurement at your water point
  1. Check the pipe

    Dimensions, material and a usable mounting position

  2. Check the reading

    Correct setup, acoustic signal and operating condition

  3. Save the site record

    Settings, units, time and the measured water point

Selection sketch: repeat the pipe and measurement checks whenever the kit moves. This does not specify a transducer spacing or pipe size.

Choose around the way the meter will be used

For a technician visiting several water points, a portable instrument can be a practical starting point. For a pipe that needs continuous records, consider a fixed installation with a documented power and data connection. Ask whether the portable kit includes the transducers, mounting fixture, cables, charger and recording tools you need. A handheld display alone does not describe the complete working kit.

Write down the pipe details before choosing transducers

The Panametrics PT900 reference manual requires pipe dimensions, material and, where applicable, lining details when configuring the measurement. Treat the nominal pipe label as a starting point. Ask the site team for the actual outside diameter and wall thickness, and record how they were established. Check the selected transducer range against those details. Do not promise that one sensor pair fits every pipe in a multisite project.

  • List each pipe rather than only the smallest and largest nominal sizes.
  • Photograph the available mounting area and nearby fittings.
  • Confirm the liquid and its normal operating conditions.

Find a measurement position, not just a place to attach the clamps

The same reference manual gives model-specific straight-run, alignment, spacing and couplant instructions. These are installation requirements, not optional accessories. Follow the selected manufacturer’s method rather than copying a spacing or straight-run number from another meter. Include pipe filling and entrained air in the site review. If the reading is unstable, retain the instrument’s diagnostic information instead of reporting an apparently precise flow number.

Moving the kit also moves the setup responsibility

Keep a separate record for each water point. Before recording at the next pipe, confirm its settings and label the new session. Otherwise two readings can look comparable while using different dimensions, units or measuring conditions. For a repeat visit, the earlier record is useful only if the pipe and operating arrangement are still the same. Agree what evidence the site operator needs before accepting a measurement.

Decide what happens after a low-flow reading

A flow reading can help an operator investigate a pump. It does not by itself define a protection circuit. If the requirement is automatic shutdown, ask separately about the local controller, approved signal connection, fault behavior and commissioning checks. Confirm continuous output and logging capabilities on the exact meter configuration. For a selection review, send the pipe list, a mounting photo and whether the job is occasional checking or permanent monitoring.

Which arrangement fits the job?
NeedReview before selection
Occasional checks at several sitesPortable kit, pipe-by-pipe compatibility and saved settings
Continuous history on one pipeFixed installation, power, recording and documented output
No suitable mounting positionAnother location or a different measurement method
Automatic pump shutdownA separately reviewed local protection and control arrangement

Reference documents

Common questions

Does clamp-on measurement require cutting the pipe?

External clamp-on transducers attach to the outside of a compatible pipe. Confirm the pipe, liquid and installation conditions against the selected instrument’s requirements before choosing the kit.

Can I reuse the previous site’s settings?

Only after confirming that they match the new pipe and liquid. Save a separate site record so later comparisons have the right dimensions, units and measurement conditions.