Path 1
Discrete I/O retrofit
Best for: Older equipment with run, fault or alarm contacts.
- 1Dry contacts and sensors
- 2Remote I/O
- 3Gateway or RTU
- 4Alarm workflow
Equipment status, temperature and energy monitoring for factories and plants.
Representative product-family images. The exact model, interfaces and enclosure are confirmed in the written quotation.
Planning monitoring hardware for this industry?
Send the site type, assets, signals, network and reporting target. We will return a hardware configuration for quotation.
Is this the right page?
Use this page for factory, plant, warehouse or facility retrofit projects that need equipment state, utility data or environmental alarms delivered to an existing maintenance, BMS, SCADA or IoT workflow.

Remote integration context
Representative site context. Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.
Dry contacts, controller status or documented registers for machine and utility equipment.
Current, power and energy trends used for runtime context, allocation or abnormal-load review.
Temperature, humidity, leak and cabinet conditions around equipment or critical rooms.
Device timeout, gateway heartbeat, network state and buffered records during outages.
A planning view, not a fixed bundle. Signal type, protocol, power, network and the customer endpoint are confirmed before quotation.

Field hardware
Customer system
SCADA, BMS or customer-owned platform
Path 1
Best for: Older equipment with run, fault or alarm contacts.
Path 2
Best for: Meters, controllers and instruments with documented registers.
Representative hardware
Images show representative product families. The exact model, interface, enclosure and certificates are confirmed against the project before quotation.

DIN-rail distributed I/O with separate PROFINET or EtherCAT coupler configurations and expansion modules selected from the project I/O schedule.

Non-invasive wireless current sensing for retrofit load monitoring, with reviewed single-phase 100 A / 300 A and three-phase 300 A / 500 A / 1000 A configurations.

Battery-powered LoRaWAN monitoring node with an external three-axis acceleration probe and built-in ambient temperature and humidity sensing.

Panel instrument for local temperature and humidity indication, with the probe, range and analog or RS485 output selected for the project.

Connect RS485, RS232 or RS422 field devices to Ethernet with 1-, 2- or 8-port serial-server options for Modbus bridging and direct IP communication.

DIN-rail gateway for collecting Modbus data from RS485 / RS232 devices and sending it to MQTT, Modbus or OPC UA systems over Ethernet, optional 4G or Wi-Fi.
Representative product-family images. Exact model, interfaces and enclosure are confirmed in the written quote.
Often yes. Dry contacts, current sensors or supported serial interfaces can provide a monitoring path after the available signals are reviewed.
The public scope is monitoring hardware and data acquisition. Safety logic and machine control remain with the machine builder or responsible integrator.
Yes when cable distance, addresses, polling load, isolation and gateway capacity are suitable for the planned point list.