Path 1
Existing inverter data
Best for: Sites with documented Modbus registers and a stable local network.
- 1Inverter register map
- 2RS485 or Ethernet gateway
- 3Data normalization
- 4Customer platform
Generation, metering and yield monitoring for solar sites and energy assets.
Representative product-family images. The exact model, interfaces and enclosure are confirmed in the written quotation.
Planning monitoring hardware for this industry?
Send the site type, assets, signals, network and reporting target. We will return a hardware configuration for quotation.
Is this the right page?
Use this page for distributed solar, facility metering or remote energy assets where the buying task is to collect trusted meter, inverter and weather data without replacing working field equipment.

Facility metering context
Representative site context. Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.
Import, export, active energy, power and phase data from meters or supported inverter registers.
Irradiance, module or ambient temperature and selected weather variables used to interpret generation trends.
Inverter faults, breaker or contact states, gateway heartbeat and site power alarms.
Timestamp, polling interval, missing-device alarms and register scaling for repeatable reporting.
A planning view, not a fixed bundle. Signal type, protocol, power, network and the customer endpoint are confirmed before quotation.
Customer system
SCADA, BMS or customer-owned platform
Path 1
Best for: Sites with documented Modbus registers and a stable local network.
Path 2
Best for: Projects that require a separate measurement point.
Representative hardware
Images show representative product families. The exact model, interface, enclosure and certificates are confirmed against the project before quotation.

Direct-connected three-phase four-wire energy meter for circuits up to 100 A, with an RS485 hardware option for verified remote-reading integrations.

Four-module three-phase DIN-rail meter family for panel energy monitoring, with direct-connected 80 A or 100 A configurations and RS485 Modbus on selected variants.

ISO 9060:2018 Class C thermopile pyranometer for 0–2000 W/m² global solar irradiance, with the output configuration selected for the site logger or RTU.

Off-grid automatic weather station kit with six-parameter sensing, RS485 Modbus, site-sized solar power and a project-selected LoRaWAN or 4G backhaul.

Connect RS485, RS232 or RS422 field devices to Ethernet with 1-, 2- or 8-port serial-server options for Modbus bridging and direct IP communication.

Cellular RTU gateway for pump stations, water telemetry and remote industrial monitoring — collects RS485, analog and digital signals and uploads data over 4G LTE.
Representative product-family images. Exact model, interfaces and enclosure are confirmed in the written quote.
Yes when the device exposes a documented interface and register map. Share the exact protocol documents before gateway selection.
No. It is useful when irradiance and environmental context are needed to explain performance, but the required variables should follow the project objective.
Yes when you provide the protocol, endpoint, authentication method and payload requirements for review.