Farm Pump-Shelter Leak & Alarm Monitoring Kit

Collect leak indications and existing alarm contacts at a farm pump shelter or irrigation control room, with a defined route to the farm monitoring system.

LoRaWAN Water Leak Sensor
A leak-sensing point reports water at its installed position; placement follows the pump-shelter layout.

Place leak-sensing points around the areas that need an alarm, then list the run and fault contacts available at the pump panel. Keep those observations separate from the local pump-control and protective circuits.

01

At the shelter

Place the LoRaWAN leak-sensing points and identify separate pump-panel contacts.

02

Along each data path

Leak-sensor radio messages use a compatible LoRaWAN gateway, network server and decoder. Wired panel contacts use their own RTU inputs.

03

At the alarm destination

Assign the point names, recipients and alarm/reset checks.

Choose the arrangement for your farm

A leak alarm at one location

Place the battery-powered remote probe where water needs to trigger an alarm. The sensor reports periodic status and leak events over LoRaWAN.

The radio and receiving-system path

Match the sensor and gateway frequency plan, field coverage, network server and decoder. Map the leak state and device identity into the receiving system.

Pump-panel status alongside the leak readings

Use a separate RTU path for available run and fault contacts. Count the required inputs and document their normal and alarm states.

Equipment in the plan

Information for your equipment list

  • Country and pump-shelter count
  • Layout or photos of the areas needing leak detection
  • Available leak, run and fault outputs
  • Power, network and alarm destination

What the project plan covers

  • Leak-point and panel-input list
  • LoRaWAN sensor, gateway and receiving-system path
  • Separate RTU input and wiring map for panel contacts
  • Normal, alarm and reset test checklist

Order individual devices or plan the equipment, data connection and local installation together. SunGene handles equipment selection and agreed integration work; the local team handles site installation and safety.

Checks at the first measurement point

  • Test the selected leak point and its reported alarm state.
  • Check each panel contact against its normal and fault condition.
  • Check alarm naming, receipt and reset using the agreed receiving system.

Use these checks to agree the sample or first-site acceptance plan.

Questions about this configuration

Will this configuration stop a pump when a leak is detected?

This configuration collects and reports leak and status signals. Pump interlocks and protective actions are part of the local control design.

Can a leak sensor measure pipe flow?

No. A leak sensor reports water at its sensing point. Use a suitable flow meter when delivered water volume or flow rate is required.

What helps place the leak-sensing points?

Send a shelter layout or photographs showing pipework, drainage, the pump panel and the areas that need an alarm.

Plan the measurements across the farm