
Configurable Multi-Gas Sensor for NH3 & Odor Monitoring
Wired RS485 Modbus RTU environmental sensor with configurable NH3, odour and supporting measurement channels for protected installations.
Category: Environmental & Agriculture Sensors
Representative image
Representative configurable multi-gas sensor visual derived from a reviewed exact-model reference and independently de-identified. It is not the final ordered-model photograph; gas modules, channel count, mounting protection, calibration, wiring, markings and certificates are confirmed in the quotation.
Typical Reviewed Options
| Channel configuration | Up to 5-6 selected parameters; installed modules are confirmed in the quotation |
|---|---|
| Standard NH3 | 0-100 ppm; 0.01 ppm resolution; ±3% FS |
| High-precision NH3 | 0-10 ppm; 0.001 ppm resolution; ±2% FS |
| Standard odour | 0-50 ppm; 0.01 ppm resolution; ±3% FS |
| Data & power | RS485 Modbus RTU; 12-24 VDC |
| Timing & repeatability | 3 min warm-up; listed response <1 s; stability <±1% FS; repeatability <±2% FS |
| Environment & housing | -20 to +60 °C; 15-80% RH; ABS shell; installation protection confirmed per site |
| Use boundary | Environmental monitoring hardware; safety or regulatory use requires a separately approved instrument and method |
Select the gas modules and mounting protection before ordering
This is a configurable wired instrument. The selected channel set and installation conditions determine the final measurement package.
- Choose standard NH3 at 0-100 ppm, high-precision NH3 at 0-10 ppm, standard odour at 0-50 ppm, or another reviewed channel combination.
- Up to five or six parameters can be selected by configuration. The product is not supplied with every listed sensor module installed.
- The reviewed interface is RS485 Modbus RTU with 12-24 VDC power. There is no approved 4-20 mA, battery, LoRaWAN or integral cellular claim for this product.
- Allow at least the listed three-minute warm-up. Response, alarms and calibration performance also depend on the selected gas module, airflow, humidity and cross-interference.
- The reviewed operating range is -20 to +60 °C at 15-80% RH, but no universal outdoor or ingress-protection rating is approved. Select protected mounting or an enclosure for the actual site.
- This is not a safety-certified gas detector. Safety or regulatory alarms require an approved instrument and method for the jurisdiction and application.
Typical applications
- NH3 or nuisance-odour trend monitoring in protected industrial or environmental installations
- Waste-transfer, composting or livestock-area monitoring after airflow, interference and mounting are reviewed
- Multi-parameter stations combining selected gas, temperature, humidity, pressure or particulate channels
- RS485 data input to a customer PLC, RTU, SCADA or remote-monitoring gateway
Inquiries: contact@sungeneiot.com · sungeneiot.com
These are typical reviewed options for this product family, not a single orderable SKU. Final model, connectors, certificates and availability are confirmed in the quotation.