Path 1
Single remote station
Best for: One tank, well or pump station with several local inputs.
- 1Field sensors and contacts
- 2Remote I/O or cellular RTU
- 3Buffered telemetry
- 4Customer SCADA or dashboard
Remote monitoring for reservoirs, pump stations, tanks and distribution networks.
Representative product-family images. The exact model, interfaces and enclosure are confirmed in the written quotation.
Planning monitoring hardware for this industry?
Send the site type, assets, signals, network and reporting target. We will return a hardware configuration for quotation.
Is this the right page?
Use this page if you are planning hardware for tanks, reservoirs, wells, pump stations, wet wells or distribution assets and need field data delivered to an existing SCADA, dashboard or customer platform.

Water-site deployment context
Representative site context. Sensors, interfaces, enclosure, power and mounting are confirmed against the actual project before quotation.
Continuous level, independent high-high or low-low switches and refill or drawdown trends.
Run, fault, current, pressure and flow signals that distinguish a process problem from an equipment problem.
Gateway heartbeat, radio or cellular signal, power state and offline buffering for unmanned sites.
Optional pH, conductivity, turbidity or dissolved oxygen where cleaning, calibration and maintenance are defined.
A planning view, not a fixed bundle. Signal type, protocol, power, network and the customer endpoint are confirmed before quotation.
Customer system
SCADA, BMS or customer-owned platform
Path 1
Best for: One tank, well or pump station with several local inputs.
Path 2
Best for: Several low-data water points within gateway coverage.
Representative hardware
Images show representative product families. The exact model, interface, enclosure and certificates are confirmed against the project before quotation.

Cellular RTU gateway for pump stations, water telemetry and remote industrial monitoring — collects RS485, analog and digital signals and uploads data over 4G LTE.

76–81 GHz FMCW non-contact level sensor for rivers, lakes and shallow-water monitoring, with a 0.1–65 m range and RS485 Modbus RTU output.

Immersion level transmitter for tanks, reservoirs and wells where direct hydrostatic level measurement is preferred.

Bidirectional electromagnetic flow meter for conductive liquids, with selectable ±0.5% or ±0.2% accuracy and order-code options for 4-20 mA, pulse, RS485 Modbus, power and liner.

Compact stainless pressure transmitter with selectable analog output for pump stations, pipelines and industrial utility monitoring.

IP65 outdoor multi-channel LoRaWAN gateway with Ethernet / Wi-Fi, 802.3af PoE, secure MQTT and optional cellular backhaul for distributed sensor networks.
Representative product-family images. Exact model, interfaces and enclosure are confirmed in the written quote.
Often yes, when the selected gateway has the required serial, analog and digital interfaces. Send the point list so the I/O count and polling method can be checked.
Not necessarily. Data can be prepared for an existing SCADA, MQTT broker or customer platform when the endpoint and payload requirements are provided.
A battery or solar path can be evaluated from the sensor load, reporting interval, radio duty cycle, autonomy target and local solar conditions.